Specication
Electrical
Physical
Environment
Accreditation
Disposal
Input and Resolution
EU Directive 73/23/EEC (Low Voltage Directive)
BS EN 55022:1998 Class B
BS EN 55024:1998
Input to Power Supply Unit (Supplied)
100-240V (47-63Hz)
External switch-mode - Output voltage 15VDC
Input Voltage to NMS300 15-24VDC ±10%
Conforms to Low Voltage Directive
Height 160mm (6.3”) Depth 38.2mm (1.5”) Mounting Bolt: M10
Width 270mm (10.63”) Weight 1.5kg (3.3lb)
Climatic Range Storage Temperature -20°C to 70°C
Working Temperature -10°C to 50°C
Working Humidity 95% R.H. at 31°C
IP-Ingress Protection IP40 Stand Alone
CE
At the end of its life, please dispose of the NMS300 system in a safe manner applicable to electrical
goods
Do not burn
The casework is suitable for recycling. Please consult local regulations on disposal of electrical equipment
Only Spherosyn 300 or Microsyn 300 encoders can be used with the NMS300 DRO
Resolutions
Spherosyn 300 Microsyn 300
5μm (0.0002”) 2µm (0.0001”)
10μm (0.0005”) 5μm (0.0002”)
20μm (0.001”) 10μm (0.0005”)
50μm (0.002”) 20μm (0.001”)
50μm (0.002”)
Newall Measurement Systems Limited reserves the right to make changes to this specication without notice