SECTION 4
CONFIGURATION/MECHANICAL INSTALLATION
4.1 AC POWER SELECTION JUMPERS
For 230V AC operation, link W1 should be installed (Remove links W2 and
W3 if fitted). For 115V AC operation, links W2 and W3 should be installed
(Remove link W1 if fitted).
Figure 4-1 Jumper on Power Transformer
AC POWER CONNECTIONS
WIRE COLOUR
AC POWER EUROPE USA
AC POWER HI BROWN BLACK
AC POWER LO BLUE WHITE
AC POWER GBD GREE/YELLOW GREEN
4.2 MODULE ADDRESS
To set module address, baud rate and mode the front lens of the module must
be carefully removed with a thin bladed screwdriver, to gain access to the DIP
switches (Figure 4-2)
Figure 4-2 DIP Switches
Note
For DIP switches 1-8
UP = 0