4 U02124ML-01-UK
2.3 TURNING IT ON
Connect the proper line voltage to the power screw terminal (TB1).
See Figure 4.3.
WARNING:
INCORRECT POWER CAN DAMAGE YOUR 6155AS MODULE
2.4 MESSAGE DISPLAY AT POWER UP
At initial Power-up the 6155AS displays a message which indicates the
following configuration details:-
i) PROGRAM REVISION CODE
i) SELECTED MODE (0, 1, 2 or 3)
ii) PRESENT INPUT LEVEL ( = HIGH, = LOW)
iii) SELECTED ADDRESS (0 to 15)
iv) SELECTED BAUD RATE (0=300,1 =1200,2=2400,3=9600)
i.e. The following display "AO_?I " would indicate
PROGRAM REVISION CODE A;
MODE 0 INPUT LINE LOW;
ADDRESS 15; and 1200 BAUD RATE Selected.