1. GENERAL RECOMMENDATIONS
For correct operation of the device:
Read this instruction manual carefully and completely before using your STERILOR Duo. Do not open
the device, only a skilled technician is authorised to do so.
Check the safety of the device: Make sure that the voltage supplied by your mains power supply
complies with the characteristics repeated in Paragraph 9.
The STERILOR Duo device must operate at the same time as the filtration system, because the water
must absolutely flow in the electrolysis cell.
When salt is added to the pool for the first time, or whenever salt is topped up, the STERILOR Duo
control box must be shut down for at least 24 hours until the salt has completely dissolved.
The device must be stopped as soon as the water temperature drops below 15°C.
In fact, at those temperatures, the titanium electrodes coated with precious metal oxides produce
more oxygen and hydrogen than chlorine.
Definition of the synoptics used in these instructions:
Important information
Sensitive point, recommendation to be followed to avoid any equipment deterioration
or operating problem.
Electrical risks, any operations relating to connections or tests may only be carried out
by accredited persons.
Earthing mandatory