DAQ X Series
X Series User Manual
NI 632x/634x/635x/636x/637x/638x/639x Devices
X Series User Manual
ni.com/manuals
DeutschFrançais
May 2019
370784K-01

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the NI 6343 and is the answer not in the manual?

NI 6343 Specifications

General IconGeneral
Analog Inputs32
Resolution16 bits
Maximum Sample Rate500 kS/s
Analog Outputs4
Output Range±10 V
Digital I/O48
Counter/Timers4
BusUSB
ConnectivityUSB
Operating Temperature Range0 °C to 55 °C
Input Range±10 V, ±5 V, ±1 V, ±200 mV

Summary

Getting Started

Safety Guidelines

Provides essential safety information for operating NI 63xx X Series devices and modules.

DAQ System Overview

DAQ Hardware

Describes the DAQ hardware, including the DAQ-STC3 digital engine and its features.

Analog Input

Analog Input on MIO X Series Devices

Describes the analog input circuitry and components for MIO X Series devices.

Analog Input Ground-Reference Settings

Details the differential, referenced single-ended, and non-referenced single-ended input settings.

Analog Input Data Acquisition Methods

Covers software-timed and hardware-timed acquisition methods, including buffered and single-point operations.

Analog Input Triggering

Explains the three analog input triggering actions: start, reference, and pause triggers.

Connecting Analog Input Signals

Summarizes recommended input configurations for floating and ground-referenced signal sources.

Analog Input Timing Signals

Details the timing signals for analog input, including AI Sample Clock and AI Convert Clock.

Counters

Counter Timing Engine

Explains the counter timing engine and the clock sources for sample-clocked operations.

Counter Input Applications

Lists various counter input applications like edge counting, pulse-width, and frequency measurements.

Pulse-Width Measurement

Describes how to measure the high and low time of a pulse using counter Gate input.

Frequency Measurement

Details methods for measuring frequency, including low, high, and reciprocal frequency measurements.

Counter Output Applications

Lists applications for counter output, including pulse train and frequency generation.

Counter Timing Signals

Details the various counter timing signals like Source, Gate, Aux, and Sample Clock.

Triggering

Triggering with a Digital Source

Explains how to generate triggers using digital signals like PFI, RTSI, or PXI_STAR.

Triggering with an Analog Source

Describes generating triggers on analog signals and the analog trigger circuit.

Troubleshooting