DAQ X Series
X Series User Manual
NI 632x/634x/635x/636x/637x/638x/639x Devices
X Series User Manual
ni.com/manuals
DeutschFrançais
May 2019
370784K-01

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the NI 6341 and is the answer not in the manual?

NI 6341 Specifications

General IconGeneral
Max Sample Rate500 kS/s
Output Range±10 V
Counter/Timers4
Resolution16 bits
Operating Temperature Range0 °C to 50 °C
Input Range±10 V, ±5 V, ±2 V, ±1 V, ±0.2 V, ±0.1 V

Summary

Getting Started with X Series DAQ Devices

Safety Guidelines

Essential safety precautions for operating X Series devices and modules.

Installation and Unpacking

Procedures for installing X Series DAQ devices and software, including unpacking.

Device Self-Calibration

Process for self-calibrating X Series DAQ devices for measurement accuracy.

DAQ System Overview

Programming Devices in Software

How to program NI measurement devices using NI-DAQmx driver software.

Connector and LED Information

I/O Connector Signal Descriptions

Detailed descriptions of signals found on the I/O connectors for X Series devices.

+5 V Power Source Details

Information on the +5 V power terminals, their ratings, and connector specifications.

Analog Input

Analog Input on MIO X Series Devices

Analog input circuitry and configuration for MIO X Series devices.

Analog Input Range

Explanation of analog input ranges and their effect on resolution.

Analog Input Ground-Reference Settings

Supported analog input ground-reference settings (DIFF, RSE, NRSE).

Analog Input Data Acquisition Methods

Software-timed vs. hardware-timed analog input acquisition methods.

Analog Output

AO Reference Selection

Setting the analog output range and reference voltage.

Analog Output Data Generation Methods

Software-timed vs. hardware-timed analog output generation methods.

Analog Output Triggering

Supported analog output triggering actions such as start and pause.

Digital I/O

Counters

PFI (Programmable Function Interface)

I/O Protection for PFI

Protection mechanisms for PFI signals against overvoltage and ESD events.

Digital Routing and Clock Generation

Bus Interface

Triggering

Where to Go from Here

Technical Support on the Web

Resources for technical support, including web resources and training.

Troubleshooting Common Issues

Analog Input Troubleshooting

Common analog input issues like crosstalk and signal drift.

NI Services and Resources

Technical Support Resources

Resources for technical support, including self-help and software support.