EasyManua.ls Logo

NI USB-6341 BNC User Manual

Default Icon
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
National Instruments PXIe-6349 Manual
Get Pricing & Availability at
ApexWaves.com
Call Today: 1-800-915-6216
Email: sales@apexwaves.com
https://www.apexwaves.com/modular-systems/national-instruments/x-series/PXIe-6349

Table of Contents

Questions and Answers:

NI USB-6341 BNC Specifications

General IconGeneral
TypeMultifunction I/O
Analog Input Channels16
Analog Input Resolution16 bits
Input Impedance1 MΩ
Analog Output Channels2
Analog Output Resolution16 bits
Analog Output Range±10 V
Output Impedance0.5 Ω
Digital I/O Channels24
Counter/Timers4
Counter/Timer Resolution32 bits
Counter/Timer Max Source Frequency100 MHz
Bus TypeUSB
Connector TypeBNC
InterfaceUSB 2.0
Analog Input Range±10 V
Analog Output Update Rate900 kS/s
Digital I/O Logic LevelsTTL
Digital I/O Max Output Current24 mA
Operating Temperature0 °C to 50 °C

Summary

Chapter 1 Getting Started

Safety Guidelines

Essential safety guidelines for operating the device.

Installation

Steps for installing the DAQ device and software.

Chapter 4 Analog Input

Analog Input Data Acquisition Methods

Software-timed vs. hardware-timed acquisition methods.

Analog Input Triggering

Triggering actions for analog input.

Connecting Floating Signal Sources

Procedures for connecting floating signal sources.

Chapter 5 Analog Output

Analog Output Data Generation Methods

Methods for performing analog output operations.

Analog Output Triggering

Triggering actions for analog output.

Chapter 6 Digital I/O

Digital Input Data Acquisition Methods

Methods for performing digital input measurements.

Digital Input Triggering

Triggering actions for digital input.

Digital Output Data Generation Methods

Methods for performing digital output operations.

Digital Output Triggering

Triggering actions for digital output.

Watchdog Timer

Feature for setting critical outputs to safe states during failures.

Chapter 7 Counters

Pulse-Width Measurement

Measuring the width of a pulse.

Frequency Measurement

Measuring frequency using counters.

Counter Triggering

Triggering actions for counters.

Chapter 8 PFI

I/O Protection

Protection against overvoltage, undervoltage, and ESD events.

Chapter 9 Digital Routing and Clock Generation

Chapter 10 Bus Interface

Direct Memory Access (DMA)

Fastest data transfer method using hardware and software.

Chapter 11 Triggering

Triggering with a Digital Source

Generating triggers on digital signals.

Triggering with an Analog Source

Generating triggers on analog signals.