EasyManua.ls Logo

NI PXIe-6363 User Manual

Default Icon
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
National Instruments PXIe-6349 Manual
Get Pricing & Availability at
ApexWaves.com
Call Today: 1-800-915-6216
Email: sales@apexwaves.com
https://www.apexwaves.com/modular-systems/national-instruments/x-series/PXIe-6349

Table of Contents

Questions and Answers:

NI PXIe-6363 Specifications

General IconGeneral
BrandNI
ModelPXIe-6363
CategoryI/O Systems
LanguageEnglish

Summary

Chapter 1: Getting Started

Safety Guidelines

Covers essential safety precautions and warnings for operating NI X Series devices.

Chapter 3: Connector and LED Information

I/O Connector Signal Descriptions

Describes signals found on the I/O connectors, including analog and digital signals.

Chapter 4: Analog Input

Analog Input on MIO X Series Devices

Details the analog input circuitry and blocks for MIO X Series devices.

Analog Input Range

Explains input ranges, resolution, and how they affect analog input accuracy.

Analog Input Ground-Reference Settings

Explains differential, referenced single-ended, and non-referenced single-ended modes.

Multichannel Scanning Considerations

Discusses issues affecting accuracy in multichannel scanning, like settling time.

Analog Input Data Acquisition Methods

Covers software-timed vs. hardware-timed acquisitions and buffered operations.

Analog Input Triggering

Details start, reference, and pause trigger actions for analog input.

Connecting Analog Input Signals

Summarizes recommended input configurations for various signal sources.

Connecting Floating Signal Sources

Explains how to connect floating signal sources using DIFF and NRSE modes.

Connecting Ground-Referenced Signal Sources

Describes methods for connecting ground-referenced sources to minimize errors.

Analog Input Timing Signals

Overview of analog input timing signals, including sample and convert clocks.

Chapter 5: Analog Output

AO Reference Selection

Explains how to set the analog output range and voltage reference.

Analog Output Data Generation Methods

Covers software-timed vs. hardware-timed generations and buffered operations.

Analog Output Triggering

Details start and pause trigger actions for analog output.

Analog Output Timing Signals

Overview of analog output timing signals for waveform generation.

AO Start Trigger Signal

Explains how to use the AO Start Trigger for waveform generation.

Chapter 6: Digital I/O

Digital Input Data Acquisition Methods

Covers software-timed vs. hardware-timed acquisitions for digital input.

Hardware-Timed Acquisitions

Details hardware-timed acquisitions using a digital sample clock.

Digital Input Triggering

Details start, reference, and pause trigger actions for digital input.

Digital Waveform Acquisition

Explains digital waveform acquisition using the DI waveform acquisition FIFO.

DI Change Detection

Details configuring DAQ to detect changes on digital input lines.

Watchdog Timer

Describes the software-configurable watchdog timer for safe states.

Digital Output Data Generation Methods

Covers software-timed vs. hardware-timed generations for digital output.

Digital Waveform Generation

Explains generating digital waveforms using the DO waveform generation FIFO.

Chapter 7: Counters

Counter Timing Engine

Details counter timing engine capabilities and clock source options.

Counter Input Applications

Lists various counter input applications like edge counting and pulse measurements.

Pulse-Width Measurement

Describes pulse-width measurements, including high/low pulse width and accuracy.

Pulse Measurement

Details pulse measurements, including high/low time and data return methods.

Frequency Measurement

Covers various methods for measuring frequency with counters.

Choosing a Method for Measuring Frequency

Guides on selecting the best frequency measurement method based on criteria.

Position Measurement

Details position measurements using quadrature and two-pulse encoders.

Two-Signal Edge-Separation Measurement

Describes measuring time between edges on two signals using Aux and Gate inputs.

Counter Output Applications

Lists counter output applications like pulse generation and frequency generation.

Pulse Train Generation

Details options for generating pulse trains, including finite and continuous modes.

Frequency Generation

Describes generating frequencies using counters or the frequency generator circuit.

Counter n Sample Clock Signal

Details the Counter n Sample Clock signal for clocked acquisitions and generations.

Default Counter/Timer Pins

Lists default NI-DAQmx counter/timer input/output assignments to PFI pins.

Chapter 8: PFI

Using PFI Terminals as Timing Input Signals

Details routing external timing signals to various X Series functions via PFI terminals.

Exporting Timing Output Signals Using PFI Terminals

Describes routing timing signals to PFI terminals configured as outputs.

Using PFI Terminals as Static Digital I/Os

Explains configuring PFI terminals for static digital input or output.

I/O Protection

Details protection against overvoltage, undervoltage, overcurrent, and ESD events.

Chapter 9: Digital Routing and Clock Generation

Synchronizing Multiple Devices

Information on synchronizing multiple X Series devices.

Using RTSI Terminals as Timing Input Signals

Explains routing external timing signals to X Series functions via RTSI terminals.

Chapter 10: Bus Interface

PCI Express/PXI Express Device Data Transfer Methods

Explains DMA and Programmed I/O for PCI Express/PXI Express data transfer.

USB Device Data Transfer Methods

Describes USB Signal Stream and Programmed I/O for USB data transfer.

Data Throughput

Covers data throughput and preventing buffer overflow errors.

Chapter 11: Triggering

Triggering with a Digital Source

Explains generating triggers using digital signals like PFI, RTSI, PXI_STAR.

Triggering with an Analog Source

Details generating triggers using analog signals, including MIO and Simultaneous MIO devices.

Analog Trigger Types

Details analog edge triggering, hysteresis, and window triggering modes.

Appendix A: Device-Specific Information

Appendix C: Troubleshooting

Analog Input

Troubleshooting common analog input issues like crosstalk and drift.

Related product manuals