Addressing the indoor unit AG-WL10
Addressing via remote control
When addressing using remote control it is possible to connect up to eight indoor units to one outdoor unit.
Set the remote control according to the table below, direct it towards the desired indoor unit and keep the buttons
"FAN" and "iFEEL" pressed for more than five seconds. If the unit has received the command, four beeps are sounded
as confirmation. When you have heard the peeps, the unit starts to work with the new address.
Indoor unitButton
HGFEDCBA
AUTO
Operating mode ( or )
18 °C17 °C16 °C15 °C14 C13 °C12 °C11 °CSet point temperature
( / )
AUTO
Air deflector ( )
ON
TiO
2
air cleaner ( )
OFF
Night program ( )
OFF
High power ( )
Addressing via DIP switches
When addressing using DIP switches it is possible to connect up to four indoor units to one outdoor unit. Set SW2
as indicated in the table.
Indoor unit
DCBA