INSTALLATION AND MAINTENANCE INSTRUCTIONSMOS GB 1337-3
NIBE™ SPLIT
431138
NIBE™ SPLIT
AMS 10-16, HBS 16, HE 30/HEV 300/HEV 500
LEK
LEK
L
E
K
LEK
LEK

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Nibe AMS 10-16 and is the answer not in the manual?

Nibe AMS 10-16 Specifications

General IconGeneral
Heating capacity10.5 kW
RefrigerantR410A
Sound power level62 dB(A)
Supply voltage400V 3N~ 50Hz
Power Supply400V 3N~ 50Hz
Sound Power Level (Outdoor Unit)62 dB(A)
TypeAir/water heat pump

Summary

General

Installation data

Details about the system installation, to be filled by the installer for warranty.

Information about the installation

Product information

NIBE SPLIT heat pump system offers energy saving and climate control.

Features of NIBE SPLIT

Highlights optimal heating factor, compact dimensions, speed-controlled pump, and integrated functions.

Principle of operation NIBE SPLIT

Explains how the heat pump system works for heating, cooling, and hot water production.

Front panel, indoor module

How to use the front panel

Guide on operating common settings and computer instructions for the heat pump system.

Menu types

Explains the different menu types (Normal, Extended, Service) for system control.

Key lock

Describes how to activate and deactivate the key lock feature on the front panel.

Comfort setting heating

Default setting

Basic heating is set using menu 2.1.2 and the 'Heating curve offset' knob. Readjustment may be needed.

Readjusting the default settings

Guides on how to adjust heating curve and offset based on room temperature in cold or warm weather.

Comfort setting cooling

General

Condition for cooling activation is 'On' in menu 9.3.3. System must manage cooling operation.

Controlling cooling mode using the room sensor

Conditions for cooling when a room sensor is connected, based on room and outdoor temperatures.

Comfort setting hot water

Available volume

Graphs showing domestic hot water volume at different water flows and stop temperatures for HEV 300 and HEV 500.

Prioritizing

How the heat pump prioritizes hot water heating, shifting to hot water mode with full output.

Extra Hot Water

Explains temporary and timed extra hot water functions, including activation methods.

Maintenance

Checking the safety valves

Instructions for checking safety valves for the water heater and the climate system.

Maintenance of AMS 10

Exterior maintenance for AMS 10, including checking grilles, ice buildup, and cleaning.

Saving tips

Tips for reducing energy consumption, such as setting appropriate temperatures and using thermostat valves correctly.

Dealing with comfort disruption

Operating mode "Add. heat only"

How to activate and deactivate 'Add. heat only' mode for heating with the immersion heater.

Emergency mode

Details on emergency mode activation and its implications for system operation.

Alarm indications

What happens in the event of an alarm?

Describes display and status lamp behavior during an alarm and how certain alarms affect operating mode.

Recommended actions

Steps for customers to identify and potentially rectify alarms, or contact an installer.

Acknowledging alarms

Methods for acknowledging alarms, including using the switch or menu, and what to do if alarms recur.

General information for the installer

Transport and storage

Guidelines for transporting and storing the outdoor module (AMS 10) and indoor modules (HBS 16, tanks).

Assembly

Installation guidelines for outdoor module, HBS 16, HE 30, and HEV 300/500 units, including placement and clearance.

Emptying the vessel

Instructions for emptying the vessel in HE 30, HEV 300, HEV 500, including notes on remaining water.

Recommended installation order

Step-by-step guide for connecting components, installing pipes, and initial setup.

Pipe installation

General

Guidelines for pipe installation according to norms, temperature limits, and the need for shut-off valves.

System requirements

Minimum configuration requirements for correct function, including climate system volume and potential need for a volume vessel.

Dimensions and pipe connections

Diagrams showing dimensions and pipe connections for HBS 16, HE 30, and HEV 300 units.

Connecting HBS 16 to tank

Procedure for connecting HBS 16 to the water heater/tank, including pipe connections and installation conditions.

Connecting the climate system

How to connect HBS 16 pipe connections (XL1, XL2) to the climate system.

Connecting the hot water heater

Requirements for connecting hot water heaters (HEV 300/500), including valves and safety valves.

Connection of external heat source

How to connect external heat sources like gas or oil boilers to HEV 300/HEV500.

Connecting refrigerant pipes (not supplied)

Instructions for installing refrigerant pipes between AMS 10 and HBS 16, including limitations.

Pressure test and leak test

Procedure for pressure testing and leak testing pipe connections between products.

Filling refrigerant

Information on refrigerant filling for AMS 10-16, including notes on installations up to 15m.

Dockings

Overview of different connection methods for NIBE SPLIT, with reference to detailed descriptions online.

Installation requirements

Table listing installation requirements for AMS 10-16, including pressure, temperature, and volume limits.

Climate system

Diagrams illustrating climate system configurations for radiator, underfloor heating, and fan convector systems.

External addition

Diagrams showing various external addition configurations: solar panels, gas boiler, oil/pellet boiler, exhaust air heat pump, wood boiler.

Electrical installation

General

General electrical installation requirements, including isolator switch, earthing, and permissions.

Connecting the supply

Instructions on connecting the incoming electricity supply to HBS 16 for 400 V 3NAC and 230 V 1AC.

Connection between HBS 16 and AMS 10-16

Detailed instructions for connecting the cable between HBS 16 and AMS 10-16.

Connection between HBS 16 and HE 30, HEV 300, HEV 500

Instructions for connecting the cable between HBS 16 and the HE 30, HEV 300, HEV 500 units.

Setting max power, electrical addition

How to set the maximum immersion heater outputs using the knob (R25) on the current limiter board.

Connecting the outside sensor

Instructions for installing and connecting the outdoor temperature sensor (BT1).

Connecting the current limiter

How to install and connect current sensors for load monitoring and the integrated current limiter.

Connecting external contacts

Instructions for connecting external contacts for functions like room temperature change and extra hot water activation.

Docking specific connection

Preparation for controlling external circulation pump, shunt, exchange valve, or external addition.

Start-up and inspection

Preparations

Connecting AMS 10-16 to HBS 16 and HBS 16 to the climate system.

Filling the climate system

Steps for filling the climate system, checking pressure gauge, and bleeding valves.

Commissioning

Step-by-step guide for commissioning the system, including checks, mode selection, and setting parameters.

Setting system flow heating

How to set system flow for heating, checking temperatures, and adjusting pump speed.

Setting system flow cooling

Recommended settings for system flow during cooling, based on output and temperature difference.

Inspection of the installation

Requirement for installation inspection before commissioning by a qualified person.

Cleaning the particle filter

Step-by-step guide to cleaning the particle filter (HQ1).

Checklist: Checks before commissioning

A comprehensive checklist for verifying all aspects of the installation before commissioning.

Control

Display

Explains the operating symbols and values shown on the current parameter display.

Menu types

Explains the different menu types (Normal, Extended, Service) for system control.

Menu management

How to navigate through menus and change parameter values using the plus, minus, and enter buttons.

Changing parameters

Step-by-step guide on how to access and change parameter values in the system menus.

Menu tree

An overview of the menu structure, showing different menus and their sub-menus.

Main menus

Descriptions of the main menu categories (1.0 to 8.0) and their functions.

Menu 9.0 [S] Service menus

Introduction to the Service menus, noting they are for expert use only.

Menu 1.0 [N] Hot water temp.

Displays current hot water temperature and settings for hot water period, start/stop temperatures, and extra hot water.

Menu 2.0 [N] Supply temp.

Settings for heating are made in the sub-menus for this menu.

Menu 5.0 [N] Heat pump

Provides readings related to the heat pump's status, including starts, run time, and temperatures.

Menu 6.0 [N] Room temperature*

Settings for room temperature, including compensation, heating system selection, and setpoint.

Menu 7.0 [N] Clock

Settings for date, time, and temperature adjustments for specific times.

Menu 8.0 [N] Other adjustments

Settings for display, language, operating mode, and load monitor are made here.

Menu 9.1.0 [S] Heat pump settings

Settings for the AMS 10 heat pump are made in the sub-menus.

Menu 9.2.0 [S] Add. heat settings

Settings for additional heat and shunt, including degree minute deficit and time factor.

Menu 9.3.0 [S] Operating settings

Settings for accessories, additional heat, floor drying, and factory reset.

Menu 9.7 [S] Reset alarm

Resets or acknowledges alarms in HBS 16.

Menu 9.8.0 [S] Alarm log

Displays alarm logs, showing the last 4 alarms in sub-menus.

Alarm list

Acknowledging alarms

Instructions on how to acknowledge alarms and what happens if an alarm recurs.

Alarm with automatic reset

Lists alarms that reset automatically when the cause is resolved.

Temperature limiter alarm

Alarms related to the temperature limiter, including possible causes.

HBS 16 alarm

Alarms specific to the HBS 16 unit, indicating potential issues like power failure or low condenser out.

AMS 10 alarm

Alarms specific to the AMS 10 unit, relating to communication errors or temperature deviations.

Hot water alarm

Alarms that block hot water production, potentially due to high temperatures or sensor faults.

Supply alarm

Alarms that switch off heating/cooling, permitting only hot water production.

Outdoor sensor alarm

Alarms related to the outdoor sensor, causing the system to run at minimum supply temperature.

Electrical circuit diagram

HBS 16

Detailed electrical circuit diagram for the HBS 16 unit.

AMS 10-16

Electrical circuit diagram for the AMS 10-16 outdoor unit.

Component positions

HBS 16

Image showing component layout and labels within the HBS 16 unit.

Component list

A comprehensive list of components, categorized by function.

HE 30, HEV 300, HEV 500

Component images and labels for HE 30, HEV 300, and HEV 500 units.

Outdoor unit

Component image and labels for the AMS 10-16 outdoor unit.

List of components

List of components for the outdoor unit, including pressostats, fans, valves, boards, and sensors.

Temperature sensor

Sensor placement

Diagrams showing the placement of temperature sensors in HBS 16, AMS 10-16, HE 30, and HEV 300/500 units.

Data for sensor in AMS 10-16

Graphs showing resistance (kΩ) vs. temperature (°C) for sensors Tho-D, Tho-S, Tho-R1, Tho-R2, and Tho-A.

Data for sensor in HBS 16

Table showing resistance (kΩ) and voltage (V) for HBS 16 sensors at different temperatures.

Dimensions

Indoor unit HBS 16

Diagrams showing dimensions and views (Under, Front, Right) of the indoor unit HBS 16.

Hot water tank HE 30

Diagrams showing dimensions and views (Right, Front, Above) of the HE 30 hot water tank.

Water heater HEV 300

Diagrams showing dimensions and views (Under, Front, Left, Above) of the HEV 300 water heater.

Water heater HEV 500

Diagrams showing dimensions and views (Front, Left, Above) of the HEV 500 water heater.

Outdoor unit AMS 10-16

Detailed dimensional drawings for the AMS 10-16 outdoor unit.

Technical specifications

NIBE SPLIT

Technical specifications for the NIBE SPLIT system regarding operating ranges, temperatures, and current.

Indoor module

Technical specifications for the indoor module (HBS 10-16/11-16), covering pump, flow, volume, pressure, and dimensions.

Tank

Technical specifications for HE 30, HEV 300, HEV 500 tanks, including immersion heater, volume, pressure, and dimensions.

Outdoor module AMS 10-16

Technical specifications for the AMS 10-16 outdoor module, including compressor, fan, defrost, pressure values, and dimensions.

Performance, HBS 16 and AMS 10-16

Performance data (Output/input/COP/EER) for heating and cooling at various temperatures.

Sound pressure levels

Information on sound pressure levels for the AMS 10 outdoor unit and factors affecting it.

Accessories

Common Accessories

Lists common accessories such as sensors, relays, and control boxes for the system.

Piping and Refrigerant Accessories

Lists accessories related to piping and refrigerant, including pipe kits and condensation pipes.

Safety Precautions

General Installation and Operation Warnings

Emphasizes qualified personnel, manual adherence, and risks of improper installation or repairs.

Refrigerant and Electrical Safety

Covers refrigerant handling, process circuit integrity, and electrical installation safety requirements.

Installation Location and Environmental Considerations

Stresses secure locations, avoiding hazardous environments, and proper ventilation.

Prohibited Installation Locations and Unit Handling

Lists prohibited locations and provides guidelines for safe unit handling and carrying.

Operational Safety and R410A Specifics

Covers operational safety measures, including refrigerant pipe handling and R410A system precautions.

Related product manuals