Default setting
The basic heating is set using menu 2.1.2 and with the
“Heating curve offset” knob.
If the required room temperature is not obtained, readjust-
ment may be necessary.
If you do not know the correct settings use the basic data
from the automatic heating control system diagram op-
posite.
Offset heating curve
Heating curve
2.1.2
9
Menu 2.1.2 Heating curve
NOTE
Wait one day between settings so that the temperat-
ures have time to stabilise.
Setting with diagrams
The diagram is based on the dimensioned outdoor tem-
perature in the area and the dimensioned flow temperat-
ure of the climate system. When these two values “meet”,
the heating control's curve coefficient can be read. This is
set under menu 2.1.2, "Heating curve". Limitations, which
are not in the diagrams, are included in the control sys-
tem's permitted min and max temperatures.
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
- 40
UTETEMPERATUR
- 10
0
10
- 5
+ 5
30
40
50
60
70
FRAMLEDNINGSTEMPERATUR
- 20 - 30
FÖRSKJUTNING
VÄRMEKURVA (-2)
VÄRMEKURVA
HEATING CURVE
OUTSIDE TEMPERATURE
SUPPLY TEMPERATURE
OFFSET HEAT CURVE -2
30
40
50
60
70
FRAMLEDNINGSTEMPERATUR
- 40
UTETEMPERATUR
- 10
0
10
- 20 - 30
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
VÄRMEKURVA
- 5
+ 5
FÖRSKJUTNING
VÄRMEKURVA (0)
HEATING CURVE
OUTSIDE TEMPERATURE
SUPPLY TEMPERATURE
OFFSET HEAT CURVE 0
1514 13 12 11 10
8
7
6
5
4
3
2
1
- 40
UTETEMPERATUR
- 10
0
10
- 5
+ 5
30
40
50
60
70
FRAMLEDNINGSTEMPERATUR
- 20 - 30
FÖRSKJUTNING
VÄRMEKURVA (+2)
9
V
Ä
RMEKURVA
HEATING CURVE
OUTSIDE TEMPERATURE
SUPPLY TEMPERATURE
OFFSET HEAT CURVE +2
NIBE™ SPLIT8
For Home Owners
Comfort setting heating