HEV 500
Ø670
259
326
397
657
688
1008
1122
1427
1695
20-55
XL4
XL8
XL3
XL9
XL18
XL19
Connection, Cold waterXL3
Connection, Hot waterXL4
Connection, Docking, in heating mediumXL8
Connection, Docking, out heating mediumXL9
Connection, CirculationXL18
Connection, CirculationXL19
Pump capacity diagram
0
0 0,05 0,10 0,15 0,20 0,25 0,30 0,35 0,40 0,45 0,50 0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90
10
20
30
40
50
60
70
N3D
$YDLODEOH SUHVVXUH
)ORZ OV
The diagram shows max. performance. This can be restric-
ted in menu 2.0.
Connection of extra circulation pump
When connecting additional circulation pump GP10, to
achieve a higher flow capacity, see alternative "Underfloor
heating systems" on page 29. Respective maximum flows
must not be exceeded.
Connecting HBS 16 to tank
It is necessary to connect a water heater or a tank to HBS
16. Pipe connections for the climate system are made at
the bottom of HBS 16.
႑
The tank HE 30, HEV 300, HEV 500 and pipework forHBS
16 must be installed indoors where the temperature
does not fall below 15 °C.
႑
Maximum pipe length between HBS 16 and HE 30, HEV
300, HEV 500 is 10 m.
႑
Connection (XL 18) on HBS 16 connected to the tank's
terminal connection (XL 18).
႑
Connection (XL 19) on HBS 16 connected to the tank's
terminal connection (XL 19).
႑
Hang HE 30 on the wall. HEV 300/HEV 500 should be
positioned on a firm surface, preferably a concrete
foundation.
႑
HEV 300/HEV 500 level can be adjusted with the help
of the adjustable feet.
႑
Ensure that there is approx. 500 mm free space in front
of and 220 mm above HE 30, HEV 300, HEV 500 for any
future service.
HE 30
LEK
;/
;/
HEV 300
LEK
;/
;/
;/
;/
21NIBE™ SPLIT
For the Installer
Pipe installation