Nibe AMS 10-16
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HEV 500
Ø670
259
326
397
657
688
1008
1122
1427
1695
20-55
XL4
XL8
XL3
XL9
XL18
XL19
Connection, Cold waterXL3
Connection, Hot waterXL4
Connection, Docking, in heating mediumXL8
Connection, Docking, out heating mediumXL9
Connection, CirculationXL18
Connection, CirculationXL19
Pump capacity diagram
0
0 0,05 0,10 0,15 0,20 0,25 0,30 0,35 0,40 0,45 0,50 0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90
10
20
30
40
50
60
70
N3D
$YDLODEOH SUHVVXUH
)ORZ OV
The diagram shows max. performance. This can be restric-
ted in menu 2.0.
Connection of extra circulation pump
When connecting additional circulation pump GP10, to
achieve a higher flow capacity, see alternative "Underfloor
heating systems" on page 29. Respective maximum flows
must not be exceeded.
Connecting HBS 16 to tank
It is necessary to connect a water heater or a tank to HBS
16. Pipe connections for the climate system are made at
the bottom of HBS 16.
The tank HE 30, HEV 300, HEV 500 and pipework forHBS
16 must be installed indoors where the temperature
does not fall below 15 °C.
Maximum pipe length between HBS 16 and HE 30, HEV
300, HEV 500 is 10 m.
Connection (XL 18) on HBS 16 connected to the tank's
terminal connection (XL 18).
Connection (XL 19) on HBS 16 connected to the tank's
terminal connection (XL 19).
Hang HE 30 on the wall. HEV 300/HEV 500 should be
positioned on a firm surface, preferably a concrete
foundation.
HEV 300/HEV 500 level can be adjusted with the help
of the adjustable feet.
Ensure that there is approx. 500 mm free space in front
of and 220 mm above HE 30, HEV 300, HEV 500 for any
future service.
HE 30
LEK
;/
;/
HEV 300
LEK
;/
;/
;/
;/
21NIBE™ SPLIT
For the Installer
Pipe installation

Table of Contents

Related product manuals