Loading...
Connection between HBS 16 and HE 30, HEV 300, HEV 500
HE 10-30/HEV 10-300/HEV 10-500
-X100
HBS 10-12/HBS 10-16
-X4
1211109NN876321
1211109NN876321
Temperaturebegränsare
-FD1-BT30
Elpatron -EB2
3x2000W
Elpatron -EB2
3x1000W
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
5G1.5 mm
2
7HPSHUDWXUH OLPLWHU
)'%7
,PPHUVLRQ KHDWHU (%
[:
,PPHUVLRQ KHDWHU (%
[:
+(  +(9  +(9 
+%6 
Setting max power, electrical addition
Setting the different maximum immersion heater outputs
is performed using the knob (R25) on the current limiter
board (AA22). Set value displayed in menu 8.3.2. The fol-
lowing table only applies when menu 9.2.8 Add. heat type
is set to "Internal power 1" (factory setting).
L3 (A)
Compressor
L2 (A)L1 (A)Max.
electric
power
Knob
posi-
tion
Immer-
sion
heater,
output
(kW)
offon
025000-0.0
0254.35.31-2.0
0258.79.72A4.0
02513143B6.0
13-13144C9.0
Setting max boiler temperature
The setting of the different maximum boiler temperatures
is made on the knob (R26) on the current limiter board
(AA22). Set value displayed in menu 9.3.1.
Knob positionBoiler temperature
A55
B60
C65
D65
E65
F65
EBV board, terminal and wiring diagram
The following connections are made on the EBV board
(AA22).
See page 67 for complete wiring diagram of board.
$$5
$$5
$$5
$$
$$;
$$;
Connecting the outside sensor
Install the outdoor temperature sensor (BT1) in the shade
on a wall facing north or north-west, so it is unaffected by
the morning sun. Connect the sensor to terminal block
X1:1 and X1:2 on the current limiter board (AA22) via cable
grommet UB4. Use a 2 core cable of at least 0.5 mm
2
.
If the outside sensor cable runs close to power cables,
shielded cable must be used.
If a conduit is used it must be sealed to prevent condensa-
tion in the sensor capsule.