Connection between HBS 16 and AMS 10-16
The cable between the units must be connected between
terminal block for incoming supply (TB) in AMS 10-16 and
terminal block (X2) in HBS 16 via cable gland (UB2).
NOTE
AMS 10-16 must be earthed before the wiring
between the units is connected.
The wiring must be attached so that the terminal
block is not put under stress.
Scale length of conductor is 8 mm.
AMS 10-16
7%
Connect phase (brown), neutral (blue), as well as earth
(yellow/green) as illustrated:
LN
123
LN23PE
NL
123
LN23PE
(AMS 1
$06
EURZQ EOXH
\HOORZJUHHQ
+%6
;
EURZQ EOXH
\HOORZJUHHQ
7%
* PP * PP
3RZHU &RPPXQLFDWLRQ
Connection between HBS 16 and HE 30, HEV
300, HEV 500
The cable between the units must be connected between
terminal block for outgoing electricity (X4) in HBS 16 and
terminal block X100 in HE 30, HEV 300, HEV 500.
Scale length of conductor is 12 mm.
33NIBE™ SPLIT
For the Installer
Electrical installation