Electrical installation
General
HBS 16 must be installed via an isolator switch with a
minimum breaking gap of 3mm.
Other electrical equipment, except the outdoor sensors,
current sensors and outdoor module AMS 10 is already
connected at the factory.
Disconnect the indoor module HBS 16 and outdoor
module AMS 10 before insulation testing the house
wiring.
For fuse ratings, see technical data, “Fuse protection”.
If the building is equipped with an earth-fault breaker,
HBS 16 should be equipped with a separate one.
Connection must not be carried out without the permis-
sion of the electricity supplier and under the supervision
of a qualified electrician.
3G6 mm
2
cable must be used for connection between
HBS 16 and AMS 10-16, for communication 3G1.5 mm
2
cable is used.
Cables must be routed so that they are not damaged by
metal edges or trapped by panels.
AMS 10-16 is equipped with a single phase compressor.
This means that phase L3 is loaded with up to 25 A dur-
ing compressor operation.
NOTE
Electrical installation and service must be carried out
under the supervision of a qualified electrician. Elec-
trical installation and wiring must be carried out in
accordance with the stipulations in force.
NOTE
The switch (SF1) must not be moved to “1” or
until the boiler has been filled with water. The circu-
lation pump and immersion heater may become
damaged.
Principle diagram, electrical installation
LPEN
1
L
2
L
3
Electrical distribution
unit
Isolator switch
Current sensor*
Incoming supply
Power and
communication cable
HE 30, HEV 300
or HEV500
HBS 16
AMS 10-16
Power and operating
cable
Cable for sensors
* Only in a 3-phase installation.
Electrical components
L
E
K
1 mm
5,5 mm
LEK
(3
$$
)$
)'4$
;
;
;
)$
;
8%
8%
8%
6)
HBS 16
)$
4$
4$
4$
HE 30
LEK
;
;
)'%7
(%
31NIBE™ SPLIT
For the Installer
Electrical installation