SYSTEM DIAGRAM
EXPLANATION
Caution
This is an outline diagram. Actual installations
must be planned according to applicable
standards.
Hot water comfortQZ1
AXC moduleAA25
Hot water circulation pumpGP11
Mixer valve, hot waterFQ3
Trim valveRN1
Non-return valveRM1
Flow line sensorBT70
Return line sensor, hot waterBT82
Temperature sensor, hot water heaterBT83
Water heaterCP1
Additional water heaterCP2
SMO S40AA35
Temperature sensor, hot waterBT6
Temperature sensor, hot water topBT7
OUTLINE DIAGRAM WITH ADDITIONAL HEAT
IN THE WATER HEATER, HWC AND
ELECTRONIC MIXING VALVE
-CP1
-QZ1-AA25
-QZ1-BT70-QZ1-FQ3
-QZ1-GP11-QZ1-RM1
-QZ1
-QZ1-RN1
-BT82
-AA35
OUTLINE DIAGRAM WITH ADDITIONAL
WATER HEATER, HWC AND ELECTRONIC
MIXING VALVE
-CP2
-CP1
-AA35-BT7
-
AA35-BT6
-QZ1-AA25
-QZ1-BT70-QZ1-FQ3
-QZ1-GP11-QZ1-RM1
-QZ1
-QZ1-RN1
-BT82
-AA35
-QZ1-BT83
ELECTRICAL CONNECTION
NOTE
Read section "Common electrical connection"
for instructions regarding electrical connection.
CONNECTION OF SENSORS AND EXTERNAL
BLOCKING
Hot water sensor, supply line (QZ1-BT70)
Connect the hot water sensor to AA5-X2:23-24.
24 23 22 21 20 19 18 17 16 15 14 13
Temperature sensor, hot water comfort, return line
(QZ1-BT82)
Connect the temperature sensor to AA5-X2:17-18.
24 23 22 21 20 19 18 17 16 15 14 13
Temperature sensor, hot water heater (QZ1-BT83)
Connect the temperature sensor to AA5-X2:19-20.
24 23 22 21 20 19 18 17 16 15 14 13
23AXC 30 S-series | GB