F1145 for heating systems, any accessories as well as additional heaters
NIBE AB - Energy systems Box 14, SE-285 21 Markaryd www.nibe.eu
ODM GB 1010-1
M10788
PAGE 1 (5)
Application
Houses with water-borne heating systems.
Function
F1145 prioritises hot water charging. The
heat pump is controlled by the outdoor
sensor (BT1) in combination with the in-
ternal ow sensor. The internal immersion
heater is connected automatically when the
energy requirement exceeds the capacity of
the heat pump.
Heating system 2
The external circulation pump (EP21-GP20)
is dimensioned for the under oor heat-
ing system’s demand. The ow through
the heat pump is adjusted using the heat
medium pump and any applicable control
valve.
NOTE!! In cases where the system volume
in the heating system is below 20 l/kW
(compressor output) and/or heating me-
dium ow is choked uncontrolled, a UKV
tank is installed as a volume increaser. For
only under oor heating systems and UKV,
3 connections on the UKV tank must be
used according to its installation instruc-
tions.
Note! This is an outline diagram. Actual
installations must be planned according to
applicable standards.
See the appropriate “Installer manual” for
more information.
Outline diagram
-QM31
-QM32
-FL3
-QM42
-QM12
-CM2
-HQ1
Lables according to IEC 61346-2
-QM34
-XL15
-BT1
-EB100
F1145
-FL2
-CM1
-EP12
Designations according to standard IEC 61346-2
Ground water collector
FLM
Passive cooling
Heating system 2
Pool
UKV
Extra hot water
Hot tap water
Ext. electr. heating add.
Ext. oil heating add.
Ext. district heating add.