Caution
A slow heat-releasing heating system, such as for example, underfloor
heating, may not be suitable for control using the heat pump's room
sensor.
To change the room temperature, use the control knob to set the desired
temperature in the display. Confirm the new setting by pressing the OK
button. The new temperature is shown on the right-hand side of the
symbol in the display.
Setting the temperature (without room sensors activated):
Setting range: -10 to +10
Default value: -1
The display shows the set values for heating (curve offset). To increase or
reduce the indoor temperature, increase or reduce the value on the display.
Use the control knob to set a new value. Confirm the new setting by
pressing the OK button.
The number of steps the value has to be changed to achieve a degree
change of the indoor temperature depends on the heating installation.
One step is usually enough but in some cases several steps may be required.
Setting the desired value. The new value is shown on the right-hand side
of the symbol in the display.
Caution
An increase in the room temperature can be slowed by the thermostats
for the radiators or under floor heating. Therefore, open the thermostats
fully, except in those rooms where a cooler temperature is required, e.g.
bedrooms.
If the exhaust air temperature falls below 16 °C the compressor is blocked
and electric additional heat is permitted. Heat is not recovered from the
exhaust air when the compressor is blocked.
33NIBE™ F750Chapter 3 | F750 at your service