add. heat info
add. heat info3.3
status:
time factor:
off
Information about the additional
heat's settings, operating status and
statistics can be obtained here. No
changes can be made.
The information is on several pages.
Turn the control knob to scroll
between the pages.
Menu
3.3
alarm log
alarm log 3.4
TB alarm
LP alarm
Sensor flt:BT6
Sens flt:BT20
Sensor flt:BT2
Sensor flt:BT1
To facilitate fault-finding the heat
pump operating status at alarm alerts
is stored here. You can see informa-
tion for the 10 most recent alarms.
To view the run status in the event of
an alarm, mark the alarm and press
the OK button.
alarm log 3.4
outdoor temp.
heat medium flow
heat medium return
hot water charging
condenser out
operating time
op. mode
Temperature limiter alarm(52)
-5.6 °C
30.5 °C
25.0 °C
49.0 °C
30 min
off
6.2 °C
Information about an alarm.
Menu
3.4