Selection of the fan capacity is done by connecting
the black cable to a suitable outlet on the
terminal block (22). See the section “Ventilation con-
nection” - “Fan diagram”.
Connection
1
2
3
4
5
6
7
8
9
10
Voltage (V)
100
110
125
140
155
170
185
200
215
230
When FLM 30 is placed directly above the heat pump
the power supply can be connected to the heat
pump’s terminal block. The connection plug must
however be cut off.
If FLM 30 is installed independently (together with a
FIGHTER 1110 or if the ceiling level is not high
enough to allow placement above 1210) it can be con-
nected either to an earthed 1-phase wall socket or
through permanent installation. When a permanent in-
stallation is used, FLM 30 must be preceded by a cir-
cuit-breaker.
If an insulation test is to be carried out in the building,
disconnect the exhaust air module.
■ Open the front cover by pulling it out by the lower
edge, then lifting it up.
■ Switch off the voltage by turning the switch (8)
to “0”.
■ Remove the securing screw on the electrical box
and pull out the electrical box as illustrated.
■ Select a suitable fan capacity, see below.
■ Assembly takes place in the reverse order.
NOTE!
Electrical installation and service
must be carried out under the
supervision of a qualified electrician.
Electrical installation and wiring must
be carried out in accordance with the
stipulations in force. Work behind
screwed covers may only be carried
out under the supervision of a
qualified electrician.
Black
Setting the fan capacity
Electrical connections