Climate systems and zones
Multiple climate systems are used when different supply
temperatures are required for different parts of the system,
for example when both underfloor heating and radiators are
fitted in a property.
A climate system can be divided up into several zones, which
can be allocated one or more sensors or other accessories.
A zone could be a specific room or part of larger premises.
OUTLINE DIAGRAM WITH CLIMATE SYSTEMS
AND ZONES
THS 10
THS 10
THS 10
THS 10
Climate system 2
Zone 1
Hearth
Zone 2
Climate system 1
Zone 3
The example shows a property with two climate systems.
Climate system 1 is a radiator system with two zones. Zone
1 is the controlling zone and there are two THS 10 installed,
which means that the heat pump extracts the heat from the
stove more rapidly. Zone 2 is the zone displayed, which
means that the temperature and humidity can be read off
in the myUplink app or via myuplink.com.
Climate system 2 is an underfloor heating system with one
zone, which is the controlling zone.
11RPP 10 | EN