TEMPERATURE
temperature heating1.1.1
temperature cooling1.1.2
If the house has several climate systems,
this is indicated on the display by a ther-
mometer for each system.
Choose between heating or cooling and
then set the desired temperature in the
next menu "temperature heating/cooling"
in menu 1.1.
Set the temperature (with
room sensor installed and
activated):
heating
Setting range: 5 30 °C
Default value: 20
cooling (accessory required)
Setting range: 5 30 °C
Default value: 25
Menu
1.1
The value in the display appears as a temperature in °C if the climate system is
controlled by a room sensor.
Caution
A slow heating system, such as underfloor heating, might not be
suitable for control by the electric boiler/indoor module’s room sensors.
To change the room temperature, use the control knob to set the desired tem-
perature in the display. Confirm the new setting by pressing the OK button. The
new temperature is shown on the right-hand side of the symbol in the display.
Setting the temperature (without room sensors activated):
Setting range: -10 to +10
Default value: 0
The display shows the set values for heating (curve offset). To raise or lower the
indoor temperature, increase or reduce the value on the display.
Use the control knob to set a new value. Confirm the new setting by pressing
the OK button.
27Chapter 3 | VVM 225 at your serviceNIBE VVM 225