Low system pressure
Not enough water in the climate system.
Fill the climate system with water and check for leaks. In event of
repeated filling, contact the installer.
The air/water heat pump’s compressor does not start
There is no heating or cooling demand (accessory is required for cool-
ing).
VVM 225 does not call on heating, cooling or hot water.
Compressor blocked due to the temperature conditions.
Wait until the temperature is within the product’s working range.
Minimum time between compressor starts has not been reached.
Wait for at least 30 minutes and then check if the compressor has
started.
Alarm tripped.
VVM 225 temporarily blocked, see menu 3.2 "Compressor informa-
tion".