7 – English
EN
7.9 (Professional) Counting the number of
valid combinations paired with the button
(reference digit: 7).
I1I Enter the programming password. – Press the button to
confirm. I2I Enter the digit “7”. – Press the button to con-
firm. I3I Therefore, to obtain the number of valid combinations
paired with the button, count the sequences of the buzzes
emitted by the device and read their explanation in Table 4.
Note – To find the total quantity of combinations relative to the
button, also add the combinations paired with both the
and buttons, calculated using the procedure described in
Paragraph 7.10.
7.10 (Professional) Counting the number of
valid combinations paired with the and
buttons (reference digits: 6-7).
I1I Enter the programming password. – Press the button to
confirm. I2I Enter the digits “6-7”. – Press the button to
confirm. I3I Therefore, to obtain the number of valid combina-
tions paired with the and buttons, count the sequences
of buzzes emitted by the device and read the explanations
in Table 4.
DEACTIVATING AND REACTIVATING
COMBINATIONS
This function allows for deactivating, or reactivating, all the
combinations ending with a certain number. The deactivation
does not cancel the stored combinations. • Procedures 7.11
and 7.12 can be repeated, by involving each time a group of
combinations with a different final number.
7.11 (Professional) Deactivating all combina-
tions ending with a certain number (reference
digit: 8).
I1I Enter the programming password. – Press the button
to confirm. I2I Enter the digit “8”. – Press the button to
confirm. I3I Enter the last number of the combinations to be
deactivated. – Press the button to confirm. I4I Re-enter the
last number of the combinations to be deactivated. – Press
the button to confirm. If the procedure was performed cor-
rectly, the keypad emits 3 buzzes.
7.12 (Professional) Reactivating all combina-
tions ending with a certain number (reference
digit: 9).
I1I Enter the programming password. – Press the button
to confirm. I2I Enter the digit “9”. – Press the button to
confirm. I3I Enter the last number of the combinations to be
reactivated. – Press the button to confirm. I4I Re-enter the
last number of the combinations to be reactivated. – Press
the button to confirm. If the procedure was performed cor-
rectly, the keypad emits 3 buzzes.
7.13 (Professional) Programming the number
or times a combination must to be used (reference
numbers: 1-0).