auto mode setting
VWRS KHDWLQJ
VWRS DGGLWLRQDO KHDW
ILOWHULQJ WLPH
r&
r&
KUV
DXWR PRGH VHWWLQJ 
stop heating
Setting range: -20 40 °C
Default values: 20
stop additional heat
Setting range: -20 40 °C
Default values: 15
filtering time
Setting range: 0 48 h
Default value: 24 h
Menu
4.9.2
When operating mode is set to "auto“ the heat pump selects when start and
stop of additional heat and heat production is permitted, dependent on the
average outdoor temperature.
Select the average outdoor temperatures in this menu.
You can also set the time over which (filtering time) the average temperature
is calculated. If you select 0, the present outdoor temperature is used.
Caution
It cannot be set "stop additional heat" higher than "stop heating".
NIBE™ F470Chapter 3 | F470 at your service64