Troubleshooting
6-78 Manual # 42-02-7223 C1
Silent Mode Activated
Description: Silent mode activated via Activate button (Controller > View > Configuration > Car Operation >
Devices tab), timer (System > Configuration tabs > Timer Tables) or iMonitor.
Silent Mode Deactivated (see Silent Mode Activated).
Single Channel QUAD Fault, SNG CHANNEL QUAD FLT
Description: Failure of one of the two landing system quadrature signals (DP1 or DP2).
Car Reaction: Emergency stop: Motor contactor and brake contactor immediately dropped.
Tro ubleshooting:
1. Check DP1 and DP2 wiring from the landing system to the iBox.
SOBO Did not boot correctly (Custom Event)
Description: The Svendborg SOBO iQ brake controller has not powered up properly.
Car Reaction: Car performs an emergency stop.
Tro ubleshooting:
1. Refer to the Svendborg SOBO iQ brake controller manual for troubleshooting information.
SOBO Out of Band Warning (Custom Event)
Description: The Svendborg SOBO iQ brake controller has detected an out of band condition.
Car Reaction: This is an informational event.
Tro ubleshooting:
1. Refer to the Svendborg SOBO iQ brake controller manual for troubleshooting information.
SOBO Overspeed Level One Fault (Custom Event)
Description: The Svendborg SOBO iQ brake controller has detected a motor overspeed condition.
Car Reaction: Car performs an emergency stop.
Tro ubleshooting:
1. Refer to the Svendborg SOBO iQ brake controller manual for troubleshooting information.
SOBO Speed Sensor Failure (Custom Event)
Description: The Svendborg SOBO iQ brake controller has detected a motor speed feedback failure.
Car Reaction: Car stops at next call destination.
Tro ubleshooting:
1. Refer to the Svendborg SOBO iQ brake controller manual for troubleshooting information.
SOBO Pressure Unit Failure (Custom Event)
Description: The Svendborg SOBO iQ brake controller has detected a pressure unit failure.
Car Reaction: Car performs an emergency stop.
Tro ubleshooting:
1. Refer to the Svendborg SOBO iQ brake controller manual for troubleshooting information.
Software Recall Switch Activated, SOFTWARE RECALL ON
Description: The software recall command has been activated via iMonitor.
Car Reaction: Car recalls to specified floor. Car calls and doors operate per recall command parameters.
Troubleshooting: Check the status of the recall command and related parameters.
SPA Firmware Updated
Description: The Safety A firmware was successfully updated.
SPA Spare Event ānā (n = 1 to 8)
Description: SPA Spare Events 1 through 8 are used for testing.
SPB Firmware Updated
Description: The Safety B firmware was successfully updated.
SPC Firmware Updated
Description: The Safety C firmware was successfully updated.
Table 6.3 iControl Messages
iControl Messages