180 SI-Ethernet User Guide
Issue: 3
Motor type
Returns or sets the motor type to be used by the drive for instance 1.
Returns or sets the motor type to be used by the drive for instance 2.
Rated current
Returns or sets the rated motor current in Amps for instance 1. This attribute is linked to
Pr 0.05.007.
Set Pr 0.05.007 = RatedCurrent1 * 10.
Get RatedCurrent1 = Pr 0.05.007 / 10.
Returns or sets the rated motor current in Amps for instance 2. This attribute is linked to
Pr 0.21.007.
Set Pr 0.21.007 = RatedCurrent2 * 10.
Get RatedCurrent2 = Pr 0.21.007 / 10.
Rated voltage
Returns or sets the rated motor voltage in Volts for instance 1. This attribute is linked to
Pr 0.05.009.
Name: MotorType1
Class 0x28 Default 7
Instance 0x01 Data Type USINT
Attribute 0x03 Access Get/Set
Name: MotorType2
Class 0x28 Default 7
Instance 0x02 Data Type USINT
Attribute 0x03 Access Get/Set
Name: RatedCurrent1
Class 0x28 Default Pr 0.05.007 / 10
Instance 0x01 Data Type USINT
Attribute 0x06 Access Get/Set
Name: RatedCurrent2
Class 0x28 Default Pr 0.21.007 / 10
Instance 0x02 Data Type USINT
Attribute 0x06 Access Get/Set
Name: RatedVoltage1
Class 0x28 Default Pr 0.05.009
Instance 0x01 Data Type USINT
Attribute 0x07 Access Get/Set