Returns or sets the rated motor voltage in Volts for instance 2. This attribute is linked to
Pr 0.21.009.
Rated frequency
Returns or sets the rated motor frequency in Hertz for instance 1. This attribute is linked to
Pr 0.05.006.
Set Pr 0.05.006 = RatedFreq1 * 10.
Get RatedFreq1 = Pr 0.05.006 / 10.
Returns or sets the rated motor frequency in Hertz for instance 2. This attribute is linked to
Pr 21.006.
Set Pr 0.21.006 =RatedFreq2 * 10.
Get RatedFreq2 = Pr 0.21.006 / 10.
Base speed
Returns or sets the base speed of the motor in RPM for instance 1. This attribute is linked to
Pr 0.05.008.
Returns or sets the base speed of the motor in RPM for instance 2. This attribute is linked to
Pr 0.21.008.
Name: RatedVoltage2
Class 0x28 Default Pr 0.21.009
Instance 0x02 Data Type USINT
Attribute 0x07 Access Get/Set
Name: RatedFreq1
Class 0x28 Default Pr 0.05.006 / 10
Instance 0x01 Data Type USINT
Attribute 0x09 Access Get/Set
Name: RatedFreq2
Class 0x28 Default Pr 0.21.006 / 10
Instance 0x02 Data Type USINT
Attribute 0x09 Access Get/Set
Name: BaseSpeed1
Class 0x28 Default Pr 0.05.008
Instance 0x01 Data Type USINT
Attribute 0x0F Access Get/Set
Name: BaseSpeed2
Class 0x28 Default Pr 0.21.008
Instance 0x02 Data Type USINT
Attribute 0x0F Access Get/Set