3
STN
===================== Advanced Features ======================
View&Delete individual data in Resection
Press the [View] softkey on the calculated STN
(sigma or coordinate) screen to check the
measurements to each known point.
dHA: Distributed errors in HA to each direction
dVD: Errors in VD between measured and
calculated distance
[ESC] [ENT]
dHD: Errors in HD between measured and
calculated distance
If you need to delete a measurement (often because
of large sigma values), place the cursor on the data
(or display its detail data screen) and press the
[DEL] softkey.
After deleting it, the STN coordinate will be
recalculated automatically.
[Add] softkey shows the next PT input screen to
continue resection observations.
===========================================================
3-42