EasyManua.ls Logo

Nilfisk-Advance E 140.3 - Starting the Washer; Adjusting Pressure; Stationary Use

Nilfisk-Advance E 140.3
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Original instructions
13
Part 3:3 - Technical Data and Declaration of Conformity
Technical Data
D 130.4
D-PG 130.4
D 140.4
D-PG 140.4
E 130.3 E 140.3 E 145.3 E 150.1
Electric specications Unom 230-240 V
fnom 50 Hz
Pnom 2.1 kW 2.4 kW 2.0 kW 2.1 kW 2.3 kW
Inom 9.5 A 10 A 9 A 9.5 A 10 A
Protection Class Class I/Class
II
Class I
Protection degree IP XX IP X5
Hydraulic specications
p
nom
12.5 MPa /
125 bar
13.5 MPa /
135 bar
12.5 MPa /
125 bar
13.5 MPa /
135 bar
14.0 MPa /
140 bar
14.5 MPa /
145 bar
p
max
13.0 MPa /
130 bar
14.0 MPa /
140 bar
13.0 MPa /
130 bar
14.0 MPa /
140 bar
14.5 MPa /
145 bar
15.0 MPa /
150 bar
Q
7.5 l/min /
450 l/h
7.0 l/min /
420 l/h
7.5 l/min /
450 l/h
7.0 l/min /
420 l/h
6.6 l/min /
400 l/h
6.8 l/min /
410 l/h
Q
max
8.3 l/min / 500 l/h
Max. water inlet pressure
p
inlet max
1 Mpa / 10 bar
Max water inlet temperature
t
inlet max
60° C
Max water inlet temp. suction
mode
t
inlet max
20° C
Kick-back force
F
kickback
19.8 N 19.2 N 19.8 N 19.2 N 18.4 N 19.3 N
Weight
M
machine
13.8 kg 17.8 kg 18.6 kg 19.8 kg 20.6 kg
Hand-arm vibration according to:
Standard nozzle
a
ha
< 2.5 ± 1 m/s
2
Sound pressure level LpA
LpA
standard
77.2 ± 2 dB(A)
66.8 ± 2 dB(A) -
LpA
standard
71.8 ± 2 dB(A)
Guaranteed sound power level
LWA
LwA
standard
92 dB(A)
82 dB(A) -
LwA
standard
86 dB(A)
We reserve the right to make alterations.

Other manuals for Nilfisk-Advance E 140.3