Original instructions
13
Part 3:3 - Technical Data and Declaration of Conformity
Technical Data
D 130.4
D-PG 130.4
D 140.4
D-PG 140.4
E 130.3 E 140.3 E 145.3 E 150.1
Electric specications Unom 230-240 V
fnom 50 Hz
Pnom 2.1 kW 2.4 kW 2.0 kW 2.1 kW 2.3 kW
Inom 9.5 A 10 A 9 A 9.5 A 10 A
Protection Class Class I/Class
II
Class I
Protection degree IP XX IP X5
Hydraulic specications
p
nom
12.5 MPa /
125 bar
13.5 MPa /
135 bar
12.5 MPa /
125 bar
13.5 MPa /
135 bar
14.0 MPa /
140 bar
14.5 MPa /
145 bar
p
max
13.0 MPa /
130 bar
14.0 MPa /
140 bar
13.0 MPa /
130 bar
14.0 MPa /
140 bar
14.5 MPa /
145 bar
15.0 MPa /
150 bar
Q
7.5 l/min /
450 l/h
7.0 l/min /
420 l/h
7.5 l/min /
450 l/h
7.0 l/min /
420 l/h
6.6 l/min /
400 l/h
6.8 l/min /
410 l/h
Q
max
8.3 l/min / 500 l/h
Max. water inlet pressure
p
inlet max
1 Mpa / 10 bar
Max water inlet temperature
t
inlet max
60° C
Max water inlet temp. suction
mode
t
inlet max
20° C
Kick-back force
F
kickback
19.8 N 19.2 N 19.8 N 19.2 N 18.4 N 19.3 N
Weight
M
machine
13.8 kg 17.8 kg 18.6 kg 19.8 kg 20.6 kg
Hand-arm vibration according to:
Standard nozzle
a
ha
< 2.5 ± 1 m/s
2
Sound pressure level LpA
LpA
standard
77.2 ± 2 dB(A)
66.8 ± 2 dB(A) -
LpA
standard
71.8 ± 2 dB(A)
Guaranteed sound power level
LWA
LwA
standard
92 dB(A)
82 dB(A) -
LwA
standard
86 dB(A)
We reserve the right to make alterations.