9
1)
Options / model variants
Original instructions
MC 5M - MC 6P - MC 7P
3.6 Electrical connection
CAUTION!
Before connecting devices with
voltage changeover: Check that
the pre-selected voltage on the
machine corresponds with the
voltage of the electrical instal-
lation. Otherwise the electrical
devices of the machine can be
destroyed
1)
.
NOTE!
In the case of poor water quality
(sand, etc.), we recommend that
a fine water filter is fitted to the
machine. Max 50 Micron filter.
We recommend the use of a tex-
tile-reinforced water hose with a
nominal diameter of min. 3/4"
(19 mm).
CAUTION!
When using a cord reel:
Unwind the cord completely.
CAUTION!
The cleaner may only be con-
nected to a correctly installed
electrical installation.
1. Observe safety instructions
in chapter 1.
2. Put the plug into the electri-
cal socket.
400V
400V
230V
230V
230V / 400V
(220V /440V)
Nilfisk
,
3.6.1 Releasing the cable 1. Turn the cable hook (A).
2. Release the cable (B).
3. Turn back the cable hook.
A
B