13
Dynamics 440-M/B1
Dynamics 840-M/B1
GB
TECHNICAL DATA
WAP SERVICE
WARRANTY
Our General Conditions of Sale
and Delivery apply for the warran-
ty and warranty period.
COMPANY ADDRESS
Wap
Reinigungssysteme GmbH & Co
Guido-Oberdorfer-Str. 2-8
89287 Bellenberg
Germany
Filter element Part No. 34931
Filter element „Special“,
filter element with non-stick coating Part No. 26736
Disposal bag Part No. 29727
Please see the „Accessories, Vacuum-Cleaner and Safety Vacuum-Cleaner
Systems“ chapter of our catalogue for the wide range of accessories
available for this vacuum cleaner.
ACCESSORIES, ADDITIONAL
EQUIPMENT
Dynamics
440-M/B1
Dynamics
840-M/B1
Voltage volts 400 400
Frequency Hz 50 50
Power connection 3-phase w/o neutral, 3-phase w/o neutral,
clockwise phase sequence clockwise phase sequence
Connected load max. watts 4000 2 x 4000
Connected load (IEC) watts 3300 2 x 3300
Volume flow (air) max. m
3
/h 432 774
max. l/min 7200 12900
Vacuum max. hPa 230 230
Filter surface area m
2
55
Filter blow-off % 99.9 99.9
Compressed air (oil, water and dust-free)
Flow pressure before solenoid valve bar 3.5 - 4 3.5 - 4
Flow pressure after/without solenoid valve bar 1 1
Air consumption (at atmospheric pressure) m³/h 35 - 40 35 - 40
Measuring surface sound pressure level
at 1 m distance as per DIN 45 635,
Part 1 (4/84) in open field at maximum
volume flow dB(A) 70 72
Tank volume l 100 100
Power cable m 5 5
Suction hose diameter mm 70 70
Width mm 750 750
Depth mm 1250 1250
Height mm 1350 1350
Weight kg 195 245
Protection class I I
Protection type (splash-proof) IP 54 IP 54
Radio-interference suppression level EN 55014 EN 55014
EN 61000-3-2 EN 61000-3-2
EN 61000-3-3 EN 61000-3-3
EN 55104 EN 55104