is empty
tothetop
ECOSWITCHlightsupwhenoperated,butthezonesdonotreact
Cause Action
Morethanonefunction
pressedatonce.
IfmorethanoneswitchontheECOSWITCHare
pressedatonce,the zoneswillnotreact,eventhough
theECOSWITCHlightsup.Trypressingclosertot he
corner.
«Disableoverrides»is
activatedinthezo ne,
lockingittoNormalWeekly
Program.
Checkthezoneoverviewtoseeifthezoneislockedto
NormalWeeklyProgram.
tothetop
MySafirGlassheaterorR80TXF700isflashinggreen,althoughtheheateris
notsupposedtobeinfrostprotectionmode
Cause Action
Notemperaturesensor
addedtothezone.
AddanECOSWITCHandche ckthecheckboxforusingit
asa temperaturesensorinthesamezoneastheSafir/R80
TXF700
Thetemperature sensor
is outofrangefrom
ECOHUB.
Ifthetempe raturese nsorisoutofrangea nd doe snot
reportbacktoECOHUBinseveralhours,theheaters
conne ctedtothesensorwillautomaticallygointofrost
protectionmode.
TrymovingtheECOSWITCHandECOHUBclosertogether.
Somebuildingmaterials,likereinforcedconcrete,massive
timberetc.,mayreduc ethesignalrange.Insuchcases,
movingtheECOSWITCHorECOHUB12meterstothe
sidecouldbe enoughtoavoidtheobstacle.
Thetemperature sensor
(ECOSWITCH)batteryis
empty.
ReplacetheECOSWITCHbatteryandtryagain.
ThezoneusesaTCU700
orTXB700room
thermostat,butSafir/R80
TXF700receiversare
alsoinstalledonthe
ECOHUB.
WhenusingaTCU700orTXB700roomthermostat,the
heaters(Safir/R80TXF700)mustbeaddedtotheroo m
thermostatandNOTtotheECOHUB.Onlytheroom
thermostatisaddedtoECOHUB.