NORAUTO Booster - Post-Start and Clamp Removal; Smart Clamps and USB Output

NORAUTO Booster
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
77 78
EN
battery is over 3 bars, wait 3 minutes to try again.
7. After the engine is successfully started, first pull the “smart clamps” off
the device and then remove the clamps from the car battery.
8. Charge the unit immediately after each use.
SMART CLAMPS
SN
GREEN
LED
RED
LED
AUDIBLE
WARNING
STATUS
1 Flash Flash Off No car battery connected.
2 On Off Off Connected to the standby state.
3 Off On On Short circuit alarm.
4 Off On On Reverse polarity alarm.
5 Off On On
Reverse charging voltage protection.
6 Off On On
Internal temperature exceeds 75 °C,
over temperature alarm.
7 Off On Off
Time-out alarm (connection status
exceeds 30s).
USB OUTPUT
1. Connect the USB cable to the USB output port of the device (3), 5V DC,
2.4A or 9V DC
,
2A, please refer to the technical data.
2. Short press the “POWER” button (5), USB provides 5V 2.4A output
to provide charging for mobile phones/tablets and other electronic
products.
3. The USB output will be automatically turned off after charging is
completed.
4. When the load current exceeds 2.4A, the USB output will be automatically
turned off.