EasyManua.ls Logo

Norcold 682 - Operating and User Instructions

Norcold 682
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Door in closed position
(Door Gasket Sealed)
OPERATING AND USER INSTRUCTIONS
Operation in Transit
While the refrigerator should be level when the ve-
hicle is stopped, performance during transit is not
normally affected.
Door Latch
The refrigerator's built-in door latch prevents the
door from flying open during transit. There are no
chains or slides to remember to actuate when the
THIS APPLIANCE HAS BEEN DESIGNED FOR
vehicle starts moving (See Figure 25). Always close
STORAGE OF FOODS, STORAGE OF FROZEN
the door to the sealed position (audible click) to pre-
FOODS AND MAKING ICE WHEN INSTALLED AS vent cooling loss and heavy frost.
Norcold cannot accept responsibility for re-
pairs, adjustment, or maintenance performed
by other than a qualified dealer or service
center. Resultant costs or related consequen-
tial problems cannot be assumed by Norcold.
The nearest qualified service location can be
furnished by a) your dealer, b) the qualified
service center list supplied with the refrigera-
tor, or c) contacting Norcold.
DIRECTED BY THIS MANUAL.
Location of Controls
Figure 24 illustrates the locations of the refrigera-
tor's operating controls. The Mode Control panel is
located above the upper door and includes the
thermostat for controlling the interior temperatures,
the switches which select the operating mode, and
an area which continuously displays the selected op-
erating mode. On the divider panel, located between
the two doors, is the High Humidity and Storage switch.
See following paragraphs for a description. The light
switch, which is located in this area, automatically ac-
tivates the cabinet light when the lower door opens.
Figure 24
Leveling
Norcold refrigerators do not require critical leveling
such as required by other absorption type refrigerators.
Normal vehicle leveling to provide comfort for the
occupants is satisfactory for refrigerator operation.
This will be well within the refrigerator's operation
limits of 3 degrees off-level side to side and 6 de-
grees off-level front to back.
Figure 25
Door Latch in Sealed Position
Mode Selector
This refrigerator is equipped with Norcold's exclu-
sive Mode Selector. A description of each of these
selections follows:
AUTO: The refrigerator will operate on 120 volts
AC so long as AC power is available to the
refrigerator. If AC power is lost (or discon-
nected), the Selector will automatically
switch to gas operation. As soon as AC
power is restored, the Selector automat-
ically switches back to AC operation (The
user does not have to manually switch the
refrigerator back to AC). When the opera-
tion is automatically switched to gas, the
burner will ignite and continue to operate
the refrigerator at the same thermostat set-
ting as set for AC power.
Note: If a 3-Way model, DC ON/DC OFF switch
must be set at DC OFF.
GAS: This selection allows the refrigerator to op-
erate on LP gas only. It will not automat-
ically switch modes regardless of whether
AC power is connected. If the flame is lost
17

Related product manuals