MODEL 982 & 9182 983 & 9183 962 & 9162 963 & 9163
DC (heater) Operation
12 VDC required to operate and maintain the operating control.
12 volts needed to operate the DC Electric (heater) and to operate the interior light and the
moisture reduction (divider) heater.
Fuses
Refrigerator Internal Fuse
DC Control Voltage
3 Amp Blade Type
AC Circuit
5 Amp 3AG (Glass)
DC Control Voltage
3 Amp Blade Type
AC Circuit
5 Amp 3AG (Glass)
DC Electric (Heater)
30 Amp Blade Type
DC Control Voltage
3 Amp Blade Type
AC Circuit
5 Amp 3AG (Glass)
DC Control Voltage
3 Amp Blade Type
AC Circuit
5 Amp 3AG (Glass)
DC Electric (Heater)
30 Amp Blade Type
DC Supply Wire Requirements
Min. Wire Size
Max. Wire Size
Min. fuse Size
Max. Fuse Size
*0-20’
**over 20’
18 AWG
18 AWG
*6 Amp
**6 Amp
10 AWG
8 AWG
*30 Amp
**40 Amp
18 AWG
18 AWG
*6 Amp
**6 Amp
10 AWG
8 AWG
*30 Amp
**40 Amp
Heater Specifications
AC Heater
Watts/Amps/Ohms
DC Heater
Watts/Amps/Ohms
Ohms reading +/- 5%
300 /2.7 /40.3 300 /2.7 /40.3
225/16/.87
300 /2.7 /40.3 300 /2.7 /40.3
225/16/.87
Additional Current Draws
Automatic Ignition
Moisture Reduction (Divider) Heater
Interior Light
.50 amps
.11 to .17 amps
.60 amps
4