EasyManua.ls Logo

Norcold 9182 - A5-AC Input Voltage Too Low; A6-AC Input Voltage Too High; Description of Alphanumeric Codes for 900 Series (Diagnostic Indicators); A7-DC Input Voltage Too Low

Norcold 9182
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A5-AC Input Voltage Too Low
AUTO MODE-2 & 3 Way Models
No code, alarm, flashing backlight or bell. Operating controls will switch to and operate in the next
available energy source.
MANUAL MODE-2 & 3-Way Models
Alarm, flashing backlight and bell active. Controls will not switch to another energy source.
Refrigerator will cease operation.
A6-AC Input Voltage Too High
AUTO MODE-3 & 3-Way Models
No code, alarm, flashing backlight or bell. Operating controls will switch to and operate in the next
available energy source
.
MANUAL MODE-2 & 3-Way Models
Alarm, flashing backlight and bell active. Controls will not switch to next energy source.
Refrigerator will cease operation.
A7-DC Input Voltage Too Low
When the voltage range is below the specifications, the control will lock-out and will not allow operation on "LP GAS"
or power the "BATT" (DC Heater) operation.
AUTO MODE-2 & 3-Way Models
Alarm, flashing backlight and bell active. Operating controls will not switch to next energy source.
Refrigerator will cease operation.
MANUAL MODE-2 & 3-Way Models
Alarm, flashing backlight and bell active. Operating controls will not switch to next energy source.
Refrigerator will cease operation.
A8-DC Input Voltage Too High
AUTO MODE-2 & 3 Way Models
No alarm, flashing backlight or bell. Code will remain on until DC input voltage corrected.
Refrigerator will operate.
MANUAL MODE-2 & 3-Way Models
No alarm, flashing backlight or bell. Code will remain on until DC input voltage corrected.
Refrigerator will operate
C1-Burner Failed Ignition and DC Heater Failed-3 Way Models Only (AUTO Mode)
In AUTO mode, if there is a burner ignition failure (Codes A1 0r A2), the control will attempt to select BATT (DC heater).
If DC heater is open, the C1 failure occurs.
3-Way Models Only
Alarm, flashing backlight and bell active. Fault code, alarm, flashing backlight and bell remain on
until the problem is corrected and the controls are reset.