8. Problem solving guide
10. Installing the appliance
4948
9.1. Normal noises
Clicking: Clicking sounds occur when the compressor switches on or off, and when the valve opens and closes.
Gurgling: Gurgling sounds occur when the cooling agent is circulating inside the pipes.
Humming: Humming sounds occur when the compressor is working. This sound can be louder during starts and stops.
9.2. Other noises
Some noises can be rectied easily by:
• Levelling the appliance and installing it on a at surface
• Moving the appliance away from adjacent units to separate them to prevent contact between the appliance
and adjacent units
• Placing the internal units (shelves, etc.) in the correct position
• Placing bottles in a stable, lying position
10.1. Before installation
Check the appliance for transport damage after unpacking. In the event of any damage, please contact the transport com-
pany to make sure that the damage is noted on the delivery documents. Do not use a damaged cooler.
After unpacking, check that all the components specied on the packing list are correct (see section 11).
Contact your dealer if the cooler is damaged or parts are missing.
10.2. Location
The appliance should be installed in a dry, well-ventilated room. The room temperature should not move above or below
the temperature range for which the appliance is designed. A high ambient temperature in a room will increase the appli-
ance’s energy consumption.
The appliance should not be installed where it is exposed to direct sunlight or directly adjacent to a heat-producing appli-
ance such as an oven or a radiator.
9. Noises
Fault
Possible cause Remedial action
The appliance is not cooling
The appliance is switching on
more frequently and for longer
periods
The interior light is not working
The display shows PE
1. Appliance is switched off
2. No electricity is being
supplied to the appliance
Vents blocked
1. Press the ON/OFF button and turn on
the appliance.
2. The fuse might be switched off or the
mains plug might not been inserted prop-
erly. Check that the plug is correctly inserted
and the fuse is switched on.
Check that the vents are not blocked or
dusty.
Go to www.norcool.co.uk
Go to www.norcool.co.uk
10.3. Temperature ranges
The appliance is designed for use within certain a temperature range (ambient temperatures), and should not be used out-
side this range. The appliance’s temperature range is stated on the rating plate inside the appliance.
Temperature range
Ambient room temperature
SN
N
ST
T
SN – ST
SN – T
+10°C to +32°C
+16°C to +32°C
+16°C to +38°C
+16°C to +43°C
+10°C to +38 °C
+10°C to +43 °C
According to the temperature specications, this product should be operated at a TEMPERATE (N) temperature class, meaning
between a +16 to 32°C ambient temperature range.