NORDAC FLEX (SK 200E ... SK 235E)Users Manual for Frequency Inverters
204 BU 0200 en-3118
Pos: 53 8 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 ...) /P500- P599 /Para meter P553 P LC Soll w erte [ SK 1 x0E, SK 2 xxE] @ 9 \mod_1448356543219_388.docx @ 266158 @ @ 1
P553 [-01]
...
[-05]
PLC setpoints
(PLC setpoints)
S P
0 ... 57
all = { 0 }
The PLC
setpoints are assigned with a function in this parameter. The settings only apply for
main setpoints and with active PLC actuation ((P350) = "On") and ((P351) = "0" or "1").
[-01] = Bus setpoint value 1
[-05] = Bus setpoint 5
Possible values which can be set:
0 =
Off
17 =
BusIO In Bits 0-7
1 =
Setpoint frequency
18 =
Curve travel calculator
2 =
Torque current limit
19 =
Set relays
3 =
Actual frequency PID
20 =
Set analogue out
4 =
Frequency addition
21 =
Setpoint position Low word
5 =
Frequency subtraction
22 =
Setpoint pos. HighWord
6 =
Current limit
23 =
Setpoint pos. Inc.LowWord
7 =
Maximum frequency
24 =
Target pos.Inc.HighWord
8 =
Actual PID frequency limited
46 =
Torque process controller setpoint
9 =
Actual PID frequency monitored
47 =
Gearing ratio
10 =
Servo mode torque
48 =
Motor temperature
11 =
Torque precontrol
49 =
Ramp time
12 =
Reserved
53 =
d-correction F process
13 =
Multiplication
54 =
d-correction Torque
14 =
Process controller actual value
55 =
d-correction F+Torque
15 =
Process controller setpoint
56 =
Acceleration time
16 =
Process controller lead
57 =
Deceleration time
#
Pos: 53 9 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenumbr uch ko mpakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1