2. Before Installing a new replace
All our products are tested according to the latest
European requirements and also to the Norwegian
standard NS 3058 and NS 3059, which include particle
tests. However, several European countries have local
regulations for installation of replaces, which change
regularly. It is the responsibility of the client that these
regulations are complied with in the country/region
where the replace is installed. Nordpeis AS is not
responsible for incorrect installation.
Important to check
(please note that this list is not exhaustive):
• distance from rebox to combustible/ammable
materials
• insulation materials/requirements between
replace surround and back wall
• size of oor plates in front of replace if required
• ue connection between rebox and chimney
• insulation requirements if ue passes through a
ammable wall
Chimney draft
Compared to older models, the clean burning replaces
of today put signicantly higher demands on the
chimney. Even the best replace will not work properly
if the chimney does not have the right dimensions or
is not in good working order. The draught is mainly
controlled by gas temperature, outside temperature, air
supply as well as the height and inner diameter of the
chimney. The diameter of the chimney should never
be less than that of the ue/chimney collar. At nominal
effect there should be a negative pressure of 12 to 25
Pascal.
The draft increases when:
• The chimney becomes warmer than the outside air
• The active length of the chimney over the hearth
increases
• There is good air supply to the combustion
It can be difcult to obtain the right draught conditions
in case the chimney is too large relative to the replace,
as the chimney does not heat up well enough. In
such cases you may want to contact professional for
evaluation of possible measures. Draught that is too
strong can be controlled with a damper. If necessary,
contact a chimney sweeper. The product is type
tested and should be connected to a chimney that is
dimensioned for the smoke gas temperature indicated
in the CE declaration. When necessary, contact a
professional in advance
Air supply
A set for fresh air supply is available as accessory.
This will ensure that the air supply to the combustion
chamber is less affected by ventilation systems,
kitchen fans and other factors which can create a
down-draught in the room. In all new construction, we
strongly recommend that it is designed and prepared for
direct supply of outside air. In older houses, the use of
fresh air supply set is also recommended. Insufcient
air supply can cause down-draught and thereby low
combustion efciency and the problems that this
entails: soot stains on the glass, inefcient use of the
wood and a soot deposits in the chimney.
Dimensional drawing
The illustrations indicate the approximate centre height
of the hole for the ue. Distortions in oors and walls
may inuence the dimensions. Dry stack the replace
without glue for accurate height and positioning of the
ue/chimney connection.
3. Technical information
All products Nordpeis have secondary combustion and
are clean burning. The combustion takes place in two
phases: First the wood burns and then the gases from
the fumes are lit by the hot air. This ensures that these
new replaces have minimal emissions of soot particles
and un-burnt gases (such as CO) and are thus better
for the environment. Clean burning replaces require
a small amount of wood in order to obtain a good heat
output. Use exclusively clean and dry wood.
Weight incl.insert 121 kg
Material insert Sheet steel
Insert S-18U
Surface treatment door/
doorframe
Heat resistant varnish
Fuel Wood logs, 25-30 cm
Operating range 4 kW nominal
Efciency 81,8%
CO % @ 13% O2 0,07
Draught system Air vent control
Combustion system
Secondary combustion (clean
burning)
Heating area 45-120 m²
Flue outlet Top and rear
Flue
Outer Ø 150 mm
*Alternative versions exsists due to
National requirements
Flue gas temperature 262 °C
Air supply
requirements (m³/h)
9-13 m
3
/h
Fuel charge 1.3 kg
Refueling interval 50 min
Opening of the air vent
control
33%
Operation Intermittent*
* Intermittent combustion refers to normal use of a replace, i.e. new
wood is inserted when the previous load has burned down to ember