Coolwave 2 Replacement Board and Contactor
3
Part 1099054-02
E 2018 Nordson Corporation
3. See Figure 4. On the main control board, disconnect the five electrical
connectors (power harness and ribbon cables).
Unclip Power Connector
Push Connector Clips Out to Release Ribbon Cables
Figure 4 Disconnecting Electrical Connectors
4. See Figure 5. Remove the six M3 screws and washers which secure
the main control board to the cabinet wall. Remove the control board
and set it aside for proper disposal (see the Control Board and
Contactor Disposal section for instructions on proper disposal.
Figure 5 Remove M3 Screws from Control Board