9
Choosing Installation Site
Chapter3.–SafetyRequirements
State of California:
The Combi Boiler must be braced, anchored or strapped to avoid moving during an earthquake. Contact local utilities for
code requirements in your area or call: 1-866-766-7489 and request instructions.
Avoid installation above gas ranges or stoves.
Avoid installation between the kitchen fan and stove. If oily fumes or a large
amount of steam are present in the installation location, take measures to
prevent the fumes and steam from entering the equipment.
Install the unit in a location where the exhaust gas ow will not be affected
by fans or range hoods.
Take care that noise and exhaust gas will not affect neighbors. Avoid
installation on common walls as the unit will make some operational noises
while it is running.
Before installing, make sure that the exhaust ue termination meets
clearance requirements proper clearances according to the National Fuel
Gas Code (ANSI Z223.1).
CAUTION