Other
The Water Heater stops burning during operation.
Are the gas and water supply valves fully open?
Is the water supply cut off?
Is the hot water fixture/faucet sufficiently open?
Is the gas being cut off by the gas meter? (Can
other gas devices such as stoves be used?)
(For LP) Is there enough gas in the tank? (Can
other gas devices such as stoves be used?)
White smoke comes out of the exhaust vent on a
cold day.
This is normal. The white smoke is actually
steam.
The hot water is turbid.
This is harmless. Small bubbles appear as the air
in the water is heated and depressurized rapidly
to atmospheric pressure.
The water appears blue.
The tub/wash-basin has turned blue.
Coloration to a blue color may be noticed from
small traces of copper ion contained in the
water and fat (furring). However, there are not
problems concerning health. Coloration of the
tub/wash-basin can be prevented by cleaning
frequently.
Frequent water discharge from the condensate
drain pipe.
Condensation forms inside the Water Heater
during operation and is discharged from the
condensate drain pipe.
Check for an Error Code on the Remote
Controller
Contact Noritz America if:
• Any other error code appears.
An error code is indicated again after the above
actions were followed.
• There are any other questions.
Error Code : 11
Cause : Ignition failure
Action : Check whether the gas valve is open. Press
the button to turn the Water Heater off,
open a hot water fixture/faucet, and turn
the Water Heater back on. If the blinking
number doesn’t return the problem is
solved.
Error Code : 90
Cause : [When supplying combustion air from the
indoors]
The air supply vent may be clogged.
Action : Check air supply vent for blockage or
obstruction. (See page 14)
Cause : Exhaust vent may be clogged.
Action : Check exhaust vent for blockage or
obstruction.
Cause : Abnormal combustion, low gas supply
pressure.
Action : Have a professional check the gas supply
pressure.
Cause : Condensate drain line may be clogged.
Action : Check condensate drain line is clogged or
frozen. If the display continues, contact
nearest Noritz agent.
Error Code : 99
Cause : Abnormal combustion
Action : Contact the nearest Noritz agent.
Error Code : C1# (# = 1-9)
Cause : Service Reminder (Notice for periodic
maintenance)
Action : This Water Heater is equipped with an
automatic service reminder.
Excessive scale build-up may cause
premature failure of the Heat Exchanger.
Excessive dust or lint build-up in the fan
and air intake may affect efficiency and
combustion performance.
Contact Noritz America for additional
information about recommended
maintenance procedures (1-866-766-
7489).
When a failure occurs, information relating to the
error blinks on the display.
If this occurs, take appropriate measures as the
following list.
Blinking
Troubleshooting