Do you have a question about the Noritz EZ111 and is the answer not in the manual?
Warning about potential fire or explosion if manual instructions are not followed, leading to property damage or injury.
Explains the meaning of safety alert symbols (DANGER, WARNING, CAUTION, NOTICE) for varying levels of risk.
Warns against storing or using flammable liquids near the water heater due to explosion and fire risks.
Alerts to severe burn risk from hot water over 125°F (52°C), especially for vulnerable individuals.
Details on the automatic ignition system and procedures for detecting and responding to gas leaks.
Specifies required clearances for indoor and outdoor installations to ensure proper ventilation and safety.
Ensures the supplied gas type and electrical rating match the appliance's requirements.
Emphasizes grounding the appliance and keeping the power cord dry and free of dust.
Informs about chemical substances in the product that may be known to cause cancer or reproductive harm.
Advises on treating water with high hardness or acidity to ensure warranty coverage and prevent scale.
Recommends actions to prevent freezing damage when the appliance is unused for extended periods.
Diagrams and labels key components for indoor and outdoor installation, including intake and exhaust pipes.
Illustrates parts included in the Flex Vent 2 in. Conversion Kit and Outdoor Vent Cap.
Details the function of the POWER, SETTINGS, and navigation buttons, and the indicators like PRIORITY and BURNER ON.
Step-by-step guide to prepare the water heater for its first use, including opening valves.
Instructions on how to turn on the unit and identify the BURNER ON indicator during combustion.
Guide on using the ▲/▼ buttons on the remote controller to set the desired hot water temperature.
Provides example temperature settings (°F and °C) for various applications like dishes or showers.
Caps the maximum output temperature to prevent excessively hot water discharge.
Instructions on how to mute or unmute the audible feedback from the remote controller buttons.
Configures the flow meter alarm to indicate when a tub is full, preventing overfilling.
Explains how the built-in freeze prevention heater operates to protect the unit from freezing.
Provides steps for extremely cold temperatures to protect the water heater and piping from freezing.
Detailed instructions for draining the water heater to prevent freezing when unused for extended periods.
Step-by-step guide for manually draining all water from the water heater and piping.
Steps for safely restarting the water heater after a period of inactivity, including filling the condensate trap.
Checks for air intake blockages, exhaust vent condition, pressure relief valve, and water leaks.
Instructions for cleaning the water drain valve and filter to ensure proper hot water flow.
Guidance on wiping the exterior of the water heater and remote controller with a damp cloth.
Addresses ignition failures, power indicator not lighting, and temperature changes after power loss.
Guidance on handling peeling protective sheets on the remote controller without affecting functionality.
Diagnoses issues with hot water not being available or experiencing temperature fluctuations.
Covers scenarios where water is too hot, not hot enough, or flow rates affect heating.
Explains minimum flow rate requirements and how flow affects heating performance.
Addresses operational stoppages, white smoke, turbid water, and blue water appearance.
Interprets error codes (11, 90, 99, C1#) and provides recommended corrective actions.
Details required information for contacting technical support and scheduling service.
Summarizes warranty coverage periods for components and parts, and the process for registration.
Explains the requirements and procedures for converting the water heater to a different gas type.
Lists model details, installation type, power requirements, materials, and safety devices.
Details gas consumption, maximum hot water capacity, and available temperature settings.
Specifies warranty periods for heat exchanger and parts/labor based on product type and installation conditions.
Provides instructions on making a warranty claim, including necessary information and notification procedures.
Lists conditions, misuse, or environmental factors that void the warranty or are excluded from coverage.
Details on how to register the Noritz product online or by phone to activate warranty coverage.
Warning about potential fire or explosion if manual instructions are not followed, leading to property damage or injury.
Explains the meaning of safety alert symbols (DANGER, WARNING, CAUTION, NOTICE) for varying levels of risk.
Warns against storing or using flammable liquids near the water heater due to explosion and fire risks.
Alerts to severe burn risk from hot water over 125°F (52°C), especially for vulnerable individuals.
Details on the automatic ignition system and procedures for detecting and responding to gas leaks.
Specifies required clearances for indoor and outdoor installations to ensure proper ventilation and safety.
Ensures the supplied gas type and electrical rating match the appliance's requirements.
Emphasizes grounding the appliance and keeping the power cord dry and free of dust.
Informs about chemical substances in the product that may be known to cause cancer or reproductive harm.
Advises on treating water with high hardness or acidity to ensure warranty coverage and prevent scale.
Recommends actions to prevent freezing damage when the appliance is unused for extended periods.
Diagrams and labels key components for indoor and outdoor installation, including intake and exhaust pipes.
Illustrates parts included in the Flex Vent 2 in. Conversion Kit and Outdoor Vent Cap.
Details the function of the POWER, SETTINGS, and navigation buttons, and the indicators like PRIORITY and BURNER ON.
Step-by-step guide to prepare the water heater for its first use, including opening valves.
Instructions on how to turn on the unit and identify the BURNER ON indicator during combustion.
Guide on using the ▲/▼ buttons on the remote controller to set the desired hot water temperature.
Provides example temperature settings (°F and °C) for various applications like dishes or showers.
Caps the maximum output temperature to prevent excessively hot water discharge.
Instructions on how to mute or unmute the audible feedback from the remote controller buttons.
Configures the flow meter alarm to indicate when a tub is full, preventing overfilling.
Explains how the built-in freeze prevention heater operates to protect the unit from freezing.
Provides steps for extremely cold temperatures to protect the water heater and piping from freezing.
Detailed instructions for draining the water heater to prevent freezing when unused for extended periods.
Step-by-step guide for manually draining all water from the water heater and piping.
Steps for safely restarting the water heater after a period of inactivity, including filling the condensate trap.
Checks for air intake blockages, exhaust vent condition, pressure relief valve, and water leaks.
Instructions for cleaning the water drain valve and filter to ensure proper hot water flow.
Guidance on wiping the exterior of the water heater and remote controller with a damp cloth.
Addresses ignition failures, power indicator not lighting, and temperature changes after power loss.
Guidance on handling peeling protective sheets on the remote controller without affecting functionality.
Diagnoses issues with hot water not being available or experiencing temperature fluctuations.
Covers scenarios where water is too hot, not hot enough, or flow rates affect heating.
Explains minimum flow rate requirements and how flow affects heating performance.
Addresses operational stoppages, white smoke, turbid water, and blue water appearance.
Interprets error codes (11, 90, 99, C1#) and provides recommended corrective actions.
Details required information for contacting technical support and scheduling service.
Summarizes warranty coverage periods for components and parts, and the process for registration.
Explains the requirements and procedures for converting the water heater to a different gas type.
Lists model details, installation type, power requirements, materials, and safety devices.
Details gas consumption, maximum hot water capacity, and available temperature settings.
Specifies warranty periods for heat exchanger and parts/labor based on product type and installation conditions.
Provides instructions on making a warranty claim, including necessary information and notification procedures.
Lists conditions, misuse, or environmental factors that void the warranty or are excluded from coverage.
Details on how to register the Noritz product online or by phone to activate warranty coverage.
The Noritz EZ111DV (GQ-C3260WX-FF US) and EZ98DV (GQ-C2860WX-FF US) are condensing tankless gas water heaters designed for residential or manufactured home applications. These devices provide on-demand hot water, eliminating the need for a storage tank and offering energy efficiency by heating water only when needed.
The primary function of these Noritz tankless water heaters is to supply continuous hot water. Unlike traditional tank-style water heaters, they do not store hot water. Instead, when a hot water fixture is opened, cold water flows into the unit, where a gas burner rapidly heats it to the desired temperature. The condensing design incorporates a secondary heat exchanger that recovers heat from the exhaust gases, improving efficiency and reducing energy consumption. This process also results in the discharge of condensate, a normal byproduct of the high-efficiency operation.
The water heater is equipped with an ignition device that automatically lights the burner, eliminating the need for a pilot light. This ensures safe and efficient operation. The unit's operation is managed via a remote controller, which allows users to set and monitor the hot water temperature. The controller also features indicators for power, burner activity, and priority settings, as well as an alarm for flow meter settings, useful for filling tubs to a preset volume.
Safety is a critical aspect of the device's design. It includes features to prevent scalding, such as temperature limiting options and warnings for high-temperature settings. The unit also incorporates freeze prevention heaters that automatically protect the internal components from freezing, even in cold environments, as long as the power supply is maintained. However, external plumbing requires additional protection in extremely cold conditions. The device is designed to conform to various safety standards, including the National Fuel Gas Code and Manufactured Home Construction and Safety Standards.
Operating the Noritz tankless water heater is straightforward, primarily managed through the remote controller (RC-7651M-A).
Regular maintenance is crucial for the longevity and efficient operation of the Noritz tankless water heater.
| Type | Tankless |
|---|---|
| Fuel Type | Natural Gas |
| Max Flow Rate | 11.1 GPM |
| Installation Type | Indoor |
| Vent Type | Direct Vent |
| Gas Type | Natural Gas or Propane |
| Maximum BTU Input | 199, 900 BTU/h |
| Voltage | 120V |
| Water Connection Size | 3/4 inch |
| Gas Connection Size | 3/4 inch |
| Venting | PVC, CPVC |
| Input BTU/h | 199, 900 BTU/h |












Loading...