49 | Operation
(User Defined Settings Continued)
Double Mode (NHTC 150-200 only)
Parallel = cylinders operate in
parallel from one set of control
signals. Sequenced = cylinders
operate in sequence from one set
of control signals. Independent =
two sets of controls signals and
each cylinder follows one of the
sets.
Drain Cool
When On the fill valve is activated
at any time that the drain valve is
activated to cool the drain water.
(Default = On)
Dfactor
Increases or decreases the drain
time used to control cylinder
water conductivity. It should not
normally need to be adjusted. A
NORTEC representative will
provide instructions if it should
need o be adjusted. (Default =
1.0)
Foam Mode
These settings can be used to
detect foaming in the cylinder and
take corrective action. Basic is a
software only setting. Advanced
requires installation of a
hardware kit. (Default = Off,
Default with Kit = Advanced)
Rapid Modu
Reserved for future development.
Do not adjust. (Default = Off)
ShortCyc
When On the software will detect
short On/Off cycles that could
prevent proper draining to control
cylinder conductivity. It will
reduce output of the unit if short
cycling is detected. (Default =
Off).
User Defined Settings
Multi Mode :Standalone
Drain Cool : On
Dfactor : 1.0
Foam Mode : Off
Rapid Modu : Off
ShortCyc : Off
Menu Set
Drain Cool : On
Drain Cool
On
Off
On
Menu Set
On
User Defined Settings
Multi Mode :Standalone
Drain Cool : On
Dfactor : 1.0
Foam Mode : Off
Rapid Modu : Off
ShortCyc : Off
Menu Set
Dfactor : 1.0
DFactor
1.0
1.0
Menu Set
1.0
User Defined Settings
Multi Mode :Standalone
Drain Cool : On
Dfactor : 1.0
Foam Mode : Off
Rapid Modu : Off
ShortCyc : Off
Menu Set
Foam Mode : Off
Foam Mode
Off
Off
Basic
Advanced
Menu Set
Off
User Defined Settings
Multi Mode :Standalone
Drain Cool : On
Dfactor : 1.0
Foam Mode : Off
Rapid Modu : Off
ShortCyc : Off
Menu Set
Rapid Modu : Off
User Defined Settings
Multi Mode :Standalone
Drain Cool : On
Dfactor : 1.0
Foam Mode : Off
Rapid Modu : Off
ShortCyc : Off
Menu Set
ShortCyc : Off
ShortCyc
Off
Off
On
Menu Set
Off
User Defined Settings
Multi Mode :Standalone
Double Mode : Parallel
Drain Cool : On
Dfactor : 1.0
Foam Mode : Off
Rapid Modu : Off
Menu Set
Double Mode : Parallel
Double Mode
Parallel
Parallel
Sequenced
Independent
Menu Set
Parallel