EasyManua.ls Logo

Nortek WRC4 - Page 20

Nortek WRC4
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
Table 4 Meaning of Each Error
Error
Error
Code
Error
Error
Code
Return air temperature sensor open/short
circuited
F1 Drive board communication error P6
evaporator temperature sensor open/short
circuited
F2 Compressor overheating protection H3
Indoor unit liquid valve temperature sensor
open/short circuited
b5 Indoor and outdoor units unmatched LP
Indoor gas valve temperature sensor open/
short circuited
b7
Communication line misconnected or
expansion valve error
dn
IPM temperature sensor open/short circuited P7
E7
Outdoor ambient temperature sensor open/
short circuited
F3 Pump-down Fo
Outdoor unit condenser mid-tube temperature
sensor open/short circuited
F4 Defrost or oil return
Discharge temperature sensor open/short
circuited
F5 Forced defrosting H1
Indoor and outdoor communication error E6 Compressor startup failure Lc
DC bus under-voltage protection PL High discharge temperature protection E4
DC bus over-voltage protection PH Overload protection E8
Compressor phase current sensing circuit
error
U1 Whole unit over-current protection E5
Compressor demagnetization protection HE Over phase current protection P5
PFC protection Hc Compressor desynchronizing H7
IPM Temperature Protection P8 IPM Current protection H5
Over-power protection L9
Compre s so r pha s e l o ss/ r e v e r s a l
protection
Ld
Sy s t e m charge s hortage o r bloc k a g e
protection
F0
Frequency restricted/reduced with whole
unit current protection
F8
Capacitor charging error PU
Frequency restricted/reduced with IPM
current protection
En
High pressure protection E1
Frequency restricted/reduced with high
discharge temperature
F9
Low pressure protection E3
Frequency restricted/reduced with anti-
freezing protection
FH
Compressor stalling LE
Frequen cy restricted/reduc ed with
overload protection
F6
Over-speeding LF
dc
Frequency restricted/reduced with IPM
temperature protection
EU
Drive board temperature sensor error PF Indoor unit full water error E9
AC contactor protection P9 Anti-freezing protection E2
Temperature drift protection PE AC input voltage abnormal PP
Sensor connection protection Pd Whole unit current sensing circuit error U5
DC bus voltage drop error U3 4-way valve reversing error U7
Outdoor fan 1 error protection L3 Motor stalling H6
Outdoor fan 2 error protection
compressor inhalation temperature sensor error
LA PG motor zero-crossing protection U8