Table 1. BayStack 5510 Switches technical specifications (continued)
RFC support
RFC 1213 (MIB-II); RFC 1493 (Bridge MIB); RFC 1573 (IF-MIB); RFC 2863 (Interfaces Group MIB);
RFC 2665 (Ethernet MIB); RFC 2737 (Entity MIBv2); RFC 2819 (RMON MIB);
RFC 1757 (RMON); RFC 1271 (RMON); RFC 1157 (SNMP); RFC 2570 (SNMPv3);
RFC 2571 (SNMP Frameworks); RFC 2573 (SNMPv3 Applications);
RFC 2574 (SNMPv3 USM); RFC 2575 (SNMPv3 VACM); RFC 2576 (SNMPv3);
RFC 2572 (SNMP Message Processing)
RFC 791 (IP); RFC 792 (ICMP); RFC 793 (TCP); RFC 783 (TFTP); RFC 826 (ARP);
RFC 768 (UDP); RFC 854 (TELNET); RFC951 (Bootp); RFC 2236 (IGMPv2);
RFC 1112 (IGMPv1); RFC 1945 (HTTP v1.0); RFC 2138 (RADIUS);
RFC 894 (IP over Ethernet); RFC 2674 (Q MIB); RFC 1058/RFC 1723 (RIPv1/v2)
;
RFC 2030 (SNTP [Simple NTP])
Electrical specifications
Input voltage (AC version): 100-240 VAC (+/- 10%) @ 47 to 63 Hz
Input power consumption (AC version): 135 W max
Input current (AC version): 1.3 A @ 115 VAC, 0.65 A @ 230VAC
Maximum thermal output: 460 BTU/hr
Environmental specifications
Operating temperature: 0° to 45°C (32° to 113°F)
Storage temperature: –25° to +70°C (-13° to 158°F)
Operating humidity: 85% maximum relative humidity, non-condensing
Storage humidity: 95% maximum relative humidity, non-condensing
Operating altitude: Up to 3,024 m (10,000 ft.) above sea level
Storage altitude: Up to 3,024 m (10,000 ft.) above sea level
Safety agency approvals
UL EN60950 (UL Listed or CSA 22.2 No. 60950 (CUL))
IEC 60950/EN 60950, CB report and certificate with all national deviations
C22.2 No. 950 (CUL) with all national deviations
UL-94-V1 flammability requirements for PC board
NOM-019 (NOM)
Electromagnetic emissions summary
Meets the following standards:
US: CFR47, Part 15, Subpart B, Class A
Canada: ICES-003, Issue 3, Class A
Australia/New Zealand: AS/NZS 3548:1995, A1:1997/A2:1997 class A
Japan: VCCI-V-3/02.04 class A
Taiwan: CNS 13438, Class A
EN55022:1998/A1:2000
EN61000-3-2:2000
EN61000-3-3:1995/A1:2001
Electromagnetic immunity
The module meets the EN55024:1998/A1:2001 standard.
Declaration of Conformity
As stated in the Declaration of Conformity, the BayStack 5510 Switch complies with the provisions
of Council Directives 89/336/EEC and 73/23/EEC.