MODEL 13000 PTOG
ITEM # 165929
Power T
ake-Off Generator
M165929A
OWNER’S MANUAL
13000 PTOG
Any Questions, Comments, or Problems?
Call Customer Service at 1-800-270-0810
Hours: Monday - Friday 7:30 AM to 5:30 PM
Saturday 7:30 to 11:30 AM CST
00293

Questions and Answers

  • J
    Joshua DavisJul 26, 2025
    What to do if there is no output voltage from my North Star 13000 PTOG?
    • T
      Tiffany KingJul 26, 2025
      If your North Star Portable Generator isn't producing any output voltage, here are a few things to check: * Ensure that the load connected to the generator is not defective; if it is, disconnect it. * Inspect all wires for breaks or looseness; replace or tighten any faulty connections. * Replace any defective receptacles. * If the engine speed is too slow, increase tractor RPMs. * Make sure that PTO is engaged.
  • J
    johnjohnsonJul 31, 2025
    What to do if the circuit breaker trips on my North Star 13000 PTOG?
    • J
      jmartinezJul 31, 2025
      If the circuit breaker trips on your North Star Portable Generator, here's what you can do: * First, disconnect the load. * If the generator is overloaded, reduce the load. See the Load Application section of this manual for details. * Replace the receptacle.
  • S
    Steven MurrayAug 4, 2025
    Why is my North Star 13000 PTOG overheating?
    • J
      John WalshAug 4, 2025
      If your North Star Portable Generator is overheating, ensure there is at least 3 feet of clearance on all sides of the generator to provide sufficient ventilation.
  • K
    Katie ByrdAug 9, 2025
    How to fix low voltage on my North Star Portable Generator?
    • J
      Jeremy PearsonAug 9, 2025
      If the voltage of your North Star Portable Generator is too low, increase the tractor RPMs or reduce the load. Refer to the Load Application section of this manual for guidance.
  • N
    Nicole GordonAug 14, 2025
    Why is the voltage too high on my North Star Portable Generator?
    • G
      gblankenshipAug 14, 2025
      If the voltage of your North Star Portable Generator is too high, reduce the load. See the Load Application section of this manual.
  • R
    Rachel BrownAug 20, 2025
    What to do for excessive gear box noise in North Star 13000 PTOG?
    • E
      elizabethsullivanAug 20, 2025
      If you are experiencing excessive gear box noise with your North Star Portable Generator, check the following: * Fill the gear box to the oil level sight if the gear oil is low or missing. * Reposition the tractor or generator to reduce the PTO driveline angle to less than 15° both vertically and horizontally. * Disassemble and reassemble the PTO driveline with CV joints synchronized if it's unsynchronized.

Summary

Specifications

ANSI Safety Definitions

Generator Features

Circuit Breakers

Details the 50A, 30A, and 20A push-to-reset circuit breakers.

Input Shaft

Describes the 1 3/8" Diameter 6 Spline Input Shaft, 540 RPM PTO driveline.

Oil Drain Plug

Specifies oil change intervals for the oil drain plug after initial use and regular service.

Rules for Safe Operations

Installation

Load Application

Starting Electric Motors

Pre-Start Up Preparations

Grounding

Operating Speed

Generator Care

Troubleshooting

North Star 13000 PTOG Specifications

General IconGeneral
BrandNorth Star
Model13000 PTOG
CategoryPortable Generator
LanguageEnglish

Related product manuals