EasyManua.ls Logo

North Star M165914W - User Manual

Default Icon
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
M165914W
Owner’s Manual
Instructions for Installation/Set-up, Operation, Servicing, & Storage
Portable, Outdoor Use-Only, Gasoline Generator
6,600 Watt Continuous (8,000 Watt Surge) Capacity
Can be used to power individual appliances plugged directly into the generator’s outlets, or as a back-
up connection to a building’s power supply (via a professionally installed UL-approved transfer switch.
WARNING
READ and UNDERSTAND this manual completely before using the generator! Failure to properly set up,
operate, and maintain this generator could result in serious injury or death from carbon monoxide poisoning,
electric shock, fire/explosion, or burns. In particular, be aware of the following hazards:
CO Poisoning
Generators give off carbon monoxide, a poisonous gas that can kill you. You CANNOT smell it, see it, or taste it.
ONLY run generator OUTDOORS and AWAY from building air intakes. NEVER run generator inside any enclosed or
semi-enclosed spaces, including homes, basements, garages, sheds, boxes, RVs, boats or pick-up truck beds. These
spaces can trap poisonous gases, EVEN if you run a fan or open windows.
Install carbon monoxide alarms inside nearby structures/buildings (battery-operated, or plug-in with battery backup).
Electric shock / Electrocution
High voltage electricity from generator can kill. DO NOT operate in wet locations. Be sure generator is properly
grounded. Use only UL-listed, outdoor-rated grounded extension cords of proper size.
NEVER plug the generator directly into a wall outlet. ANY connection to a building’s electrical system MUST
ISOLATE THE GENERATOR FROM UTILITY POWER via a UL-approved transfer switch installed by a licensed
electrician. Otherwise, back feed from the generator into the power grid could kill utility workers.
Fire / Explosion
DO NOT overload generator (per rated capacity), and OPERATE ONLY in an area with adequate cooling ventilation so
engine does not overheat. Exhaust can be extremely hot. Keep muffler at least 7’ from all combustible objects.
All fuels are flammable. Never fuel a running or hot engine. Never pump fuel directly into generator at gas station – use
approved container to transfer fuel. Ensure there are no fuel leaks, and keep sources of sparks and flames away.
ALWAYS keep a fire extinguisher rated “ABC” nearby.
STOP!
CHOOSE THE RIGHT GENERATOR FOR YOUR NEEDS. See the “Power load Planning & Management” section
of this manual to determine your power load requirements and then compare to the generator’s rated capacity.
INSPECT COMPONENTS: Closely inspect to make sure no components are missing or damaged. See the “Unpacking
& Delivery Inspection” section for instructions on whom to contact to report missing or damaged parts.
ARRANGE FOR PROFESSIONAL INSTALLATION of a transfer switch if you will be connecting the generator to
your building’s electrical system. See the “Installation/Initial Set-Up” section for more information about this
requirement.
Any Questions, Comments, Problems, or Parts Orders
Call NorthStar Product Support 1-800-270-0810
ITEM NUMBER: 165914
SERIAL NUMBER: _____________
®

Questions and Answers

  • G
    garciarobertAug 11, 2025
    What to do if my North Star Portable Generator is overheating?
    • P
      Patricia MartinAug 11, 2025
      If your North Star Portable Generator is overheating, it's recommended to have a qualified technician adjust it. Also, consider reducing the load on the generator.
  • D
    deborah86Aug 26, 2025
    What to do if a defective load is connected to my North Star Portable Generator?
    • A
      Adam ArnoldAug 26, 2025
      If there's a defective load connected to your North Star Portable Generator, disconnect the load. Reset the circuit breaker and reduce the loads connected to the generator.
  • M
    Molly ShepherdSep 2, 2025
    What to do if North Star Portable Generator engine lacks power?
    • J
      Jessica NelsonSep 2, 2025
      If your North Star Portable Generator engine lacks power, it's recommended to bring the generator to a qualified technician for adjustment.
  • C
    Christopher OwenSep 10, 2025
    Why does my North Star Portable Generator shut down during operation?
    • L
      Lydia KingSep 12, 2025
      If your North Star Portable Generator engine shuts down during operation, try reducing the load. Also, ensure there is at least 3 feet of clearance on all sides of the generator for sufficient ventilation; insufficient ventilation may be the cause of the issue.

North Star M165914W Specifications

General IconGeneral
BrandNorth Star
ModelM165914W
CategoryPortable Generator
LanguageEnglish