M165920S
Owner’s Manual
Instructions for Installation/Set-up, Operation, Servicing, & Storage
Portable, Outdoor Use-Only, Industrial Gasoline Generator
6,600 Watt Continuous (8,000 Watt Surge) Capacity
Can be used to power individual appliances plugged directly into the generator’s outlets, or as a back-up
connection to a building’s power supply (via a professionally installed UL-approved transfer switch.
WARNING
READ and UNDERSTAND this manual completely before using the generator! Failure to properly set up,
operate, and maintain this generator could result in serious injury or death from carbon monoxide poisoning,
electric shock, fire/explosion, or burns. In particular, be aware of the following hazards:
CO Poisoning
Generators give off carbon monoxide, a poisonous gas that can kill you. You CANNOT smell it, see it, or taste it.
ONLY run generator OUTDOORS and AWAY from building air intakes. NEVER run generator inside any enclosed or
semi-enclosed spaces, including homes, basements, garages, sheds, boxes, RVs, boats or pick-up truck beds. These
spaces can trap poisonous gases, EVEN if you run a fan or open windows.
Install carbon monoxide alarms inside nearby structures/buildings (battery-operated, or plug-in with battery backup).
Electric shock / Electrocution
High voltage electricity from generator can kill. DO NOT operate in wet locations. Be sure generator is properly
grounded. Use only UL-listed, outdoor-rated grounded extension cords of proper size.
NEVER plug the generator directly into a wall outlet. ANY connection to a building’s electrical system MUST
ISOLATE THE GENERATOR FROM UTILITY POWER via a UL-approved transfer switch installed by a licensed
electrician. Otherwise, back feed from the generator into the power grid could kill utility workers.
Fire / Explosion
DO NOT overload generator (per rated capacity), and OPERATE ONLY in an area with adequate cooling ventilation so
engine does not overheat. Exhaust can be extremely hot. Keep muffler at least 7’ from all combustible objects.
All fuels are flammable. Never fuel a running or hot engine. Never pump fuel directly into generator at gas station – use
approved container to transfer fuel. Ensure there are no fuel leaks, and keep sources of sparks and flames away.
ALWAYS keep a fire extinguisher rated “ABC” nearby.
STOP!
CHOOSE THE RIGHT GENERATOR FOR YOUR NEEDS. See the “Power load Planning & Management” section
of this manual to determine your power load requirements and then compare to the generator’s rated capacity.
INSPECT COMPONENTS: Closely inspect to make sure no components are missing or damaged. See the “Unpacking
& Delivery Inspection” section for instructions on whom to contact to report missing or damaged parts.
ARRANGE FOR PROFESSIONAL INSTALLATION of a transfer switch if you will be connecting the generator
to your building’s electrical system. See the “Installation/Initial Set-Up” section for more information about this
requirement.
Any Questions, Comments, Problems, or Parts Orders
Call NorthStar Product Support 1-800-270-0810
ITEM NUMBER: 165920
SERIAL NUMBER: _____________
®

Questions and Answers

  • K
    keithlucasAug 7, 2025
    How to troubleshoot a North Star Portable Generator that will not start?
    • A
      ashleycrawfordAug 7, 2025
      If your North Star Portable Generator's engine won't start, several factors could be at play. First, check the oil level and fill the crankcase to the correct level if it's low. A fouled spark plug can also prevent starting, so clean or replace it. Ensure the fuel tank isn't empty, and that the stop switch is in the ON position. Lastly, the battery may have lost its charge, needing either a recharge or replacement due to low electrolyte.
  • E
    Elizabeth HunterAug 11, 2025
    What to do if North Star Portable Generator engine lacks power?
    • N
      Nancy DavisAug 11, 2025
      If your North Star Portable Generator lacks power, the engine speed may be too slow, or the generator is overloaded. It is also possible that the idle control is not working correctly. It is recommended to bring the generator to a qualified technician for adjustment or inspection. Reduce the load if the generator is overloaded.
  • M
    michaelmartinezAug 16, 2025
    Why does my North Star Portable Generator engine shut off during operation?
    • D
      deleonrodneyAug 16, 2025
      If your North Star Portable Generator engine shuts off during operation, it could be due to the generator being overloaded; reduce the load. Alternatively, the air filter might be dirty, so clean or replace it.
  • M
    Mike MooreAug 20, 2025
    Why is there no output voltage from my North Star Portable Generator?
    • D
      Diane RobinsonAug 20, 2025
      If your North Star Portable Generator has no output voltage, first, disconnect any potentially defective loads connected to the generator. If that doesn't solve the issue, the receptacle itself might be defective and need replacement. Also, make sure that generator isn't overloaded and reduce the load if needed.
  • T
    Tiffany HowardAug 25, 2025
    What to do if North Star Portable Generator engine shuts off during operation and is out of fuel?
    • R
      Robert JonesAug 25, 2025
      If your North Star Portable Generator engine shuts off during operation and is out of fuel, ensure that the fuel tank is filled. Also, check the oil level and fill the crankcase to the proper oil level if it's low.
  • M
    meredith87Aug 28, 2025
    Why is my North Star Portable Generator overheating?
    • J
      Jose KaiserAug 28, 2025
      If your North Star Portable Generator is overheating, the engine speed may be too high. It is recommended to bring generator to a qualified technician for adjustment.
  • V
    vhernandezSep 1, 2025
    What to do if the circuit breaker trips on my North Star Portable Generator?
    • K
      kylecastilloSep 2, 2025
      If the circuit breaker trips on your North Star Portable Generator, reset the circuit breaker and reduce the loads connected to the generator.

North Star M165920S Specifications

General IconGeneral
Engine Displacement999 cc
Fuel Tank Capacity10.5 gal
Run Time at 50% Load8.5 hours
Displacement999 cc
Engine Type4-Stroke OHV
Starting SystemElectric start
AC Output120/240V
DC Output12V
Outlets4x 120V 20A (5-20R), 1x 120/240V 30A (L14-30R), 1x 120/240V 50A (CS6365)